Span Status Screen: Non-Doubler Applications; Span Status Screen (No Doubler) - ADC HiGain ELU-319 5E User Manual

Table of Contents

Advertisement

Maintenance

Span Status Screen: Non-Doubler Applications

Press
from the Maintenance Terminal Main Menu to open the Span Status screen
A
(EDU) is present, the screen reports span status for the subscriber lines between the ELU and the ERU.
TIME: 00:14:11
DATE: 01/24/00
ALARMS:
NONE
LOOPBACK: OFF
POWER LEVEL: LOW
MARGIN:
PULSE ATTN:
INS LOSS:
PPM OFFSET:
24 HOUR ES:
24 HOUR UAS:
24 HOUR BPV Seconds:
24 HOUR UAS Count:
Depending on system configuration, some information will change in
Figure 10 on page
22
SPAN STATUS
ELU
HDSL-1
HDSL-2
cur/min/max
cur/min/max
21/17/21
20/17/21
19
19
23
23
00
00
00002
00004
00016
00013
G.703 STATUS
ELU
00000
00000
(E)xit (C)lear (U)pdate (S)pan
Figure 8. Span Status Screen (No Doubler)
23.
January 26, 2000
Circuit ID#:
ERU
HDSL-1
HDSL-2
cur/min/max
cur/min/max
21/18/21
20/18/21 dB
19
19
23
23
06
05
00005
00007
00002
00001
ERU
00000
00000
150-319-205-05, Issue 5
(Figure
8). If no doubler
dB
dB
ppm
seconds
seconds
Figure
8,
Figure
9, and
ELU-319 List 5E and List 6E