Product Description
ELU-319 L
5E
IST
Figure 2
shows the card-edge connector of the ELU-319 List 5E and List 6E. Active pins are highlighted in black.

Network Management Control Bus

The ELU-319 List 5E and List 6E provides a Network Management Control Bus on Pin 7 of the card-edge
connector. This allows the various ADC Management System protocols to manage the ELU through the
HMU-319 HiGain Management Unit. Whenever the ELU-319 is under management, the MNGD message displays
periodically on the ELU-319 List 5E and List 6E front panel display.
Some ELU-319 List 5E and List 6E features are affected when it is under management. Consult
the management unit practice for further information (see
page
45).

Fuse Alarm

Pin 10 on the card-edge connector is a Fuse Alarm that is driven to -48 V whenever its onboard fuse opens. It
emulates the function of the Fuse Alarm output from Pin 10 on normal, high-density (HD) repeaters. Pin 10 is
connected to Pin 5 of the 1184 Alarm Card (Slot 1 in the HD shelf) and causes the 1184 Fuse ALM LED to light
when the Pin 10 signal is activated. Its normally floating output must never be driven above ground or below
-80 V. It can sink a current of 10 mA. The ELU-319 does not support the BPV function (Pin E) of normal HD
repeaters.
10
L
6E C
AND
IST
Figure 2. ELU-319 List 5E and List 6E Card-Edge Connector