Provisioning

P
ROVISIONING
There are two methods for provisioning the ELU-319 List 5E and List 6E:
Use the MODE and SEL buttons on the front panel
Access system settings screens through the RS-232 craft port.
No dip switches or jumpers are required to provision the ELU-319 as it contains a non-volatile RAM (NVRAM)
which stores the system option settings. System settings are retained if shelf power is lost or if the ELU-319 is
unplugged.
S
O
ETTING
PTIONS THROUGH
To provision the ELU-319 List 5E and List 6E through the MODE and SEL buttons on the front panel:
1
Press the MODE button and release it after the display changes.
The message displayed on the front panel alternates between the first system parameter and its current setting.
2
Press the SEL button to step the display through all possible settings (one at a time) of the selected parameter.
3
After the desired setting has been selected, press the MODE button.
This updates the current displayed mode to the selected setting, and then advances to the next configurable
parameter.
After the last parameter has been selected, a "Confirm? (Yes/No)" message appears on the front panel
display:
CONF NO
4
Do one of the following:
To cancel the session without saving the requested parameter changes, press the MODE button or do
nothing. (After 30 seconds, the display returns to its normal mode without saving the new changes.)
To accept the requested parameter changes, press the SEL button. (A YES message displays, and the
display returns to its normal mode after saving the new changes.)
In either case the display returns to its normal mode.

Factory Default Values

All user options can be set to the factory default values using the SEL and MODE buttons. To set the user options
to their default values:
1
Press the SEL button for 6 seconds until the following message appears:
DFLT NO
2
Press the SEL button while the DFLT NO message is displayed.
The message changes to DFLT YES indicating the factory default values are now in effect.
To terminate the DFLT mode without setting the factory default values, do one of the following:
Press the MODE button
Wait 30 seconds for the display to return to its normal state.
16
SEL
MODE
AND
January 26, 2000
150-319-205-05, Issue 5
ELU-319 List 5E and List 6E