System Settings Screen Options; Loopback Menu; Elu-319 List 5E And List 6E System Settings Screen Options - ADC HiGain ELU-319 5E User Manual

Table of Contents

Advertisement

150-319-205-05, Issue 5
S
S
YSTEM
ETTINGS
Table 15
describes the System Settings screen options and their counterpart codes for the front panel display.
Factory default settings are shown in bold.
Table 15. ELU-319 List 5E and List 6E System Settings Screen Options
Front Panel
System Settings
Display
Screen Options
Code
Power
PWRF
BER Alarm
BERT
Threshold
Loopback Timeout
LBTO
Alarm
ALM
Margin Alarm
MARG
Threshold
L
M
OOPBACK
ENU
The Loopback Menu permits you to issue loopbacks to the HiGain system. There are four possible Loopback
Menus:
Loopback Menu: No doubler
Loopback Menu: One doubler
Loopback Menu: Two doublers
Loopback Menu: Three doublers
In all instances, press
shows an example of a Loopback Menu when no doublers are present;
doublers are present.
ELU-319 List 5E and List 6E
S
O
CREEN
PTIONS
Selection
Description
DIS
Disables powering to the HDSL pair.
LOW
Keeps the HDSL line voltage at -140 V maximum for all applications.
AUTO
Allows the HDSL line voltage to automatically switch between -140 V
maximum for non-doubler applications and ±112 V for doubler applications.
HIGH
Forces the HDSL line voltage to ±112 V for all applications.
1E-6
Activates (closes) the SmartJack alarm relay contacts on pins 20 and 21 and
flashes the red STATUS LED when the BER exceeds 10
1E-7
Activates (closes) the system alarm relay contacts on pins 20 and 21 and
flashes the red STATUS LED when 10
NONE
Prevents generation of a system alarm due to BER.
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.
DIS
Opens the system alarm relay contacts if closed, and disables activation of the
system alarm relay when a system alarm condition occurs.
ENA
Enables activation of the system alarm relay when a system alarm condition
occurs.
0 to 15 dB
The Margin Alarm Threshold can only be set via the RS-232 craft port with a
terminal. It determines the minimum allowable margin below which a system
alarm can occur. Zero disables the alarm.
4dB
Default value
from the Maintenance Terminal Main Menu to display the Loopback Menu.
D
January 26, 2000
-6
.
-6
-7
> BER >10
.
Figure 14
shows an example when three
Maintenance
Figure 13
29