11. Removal Procedure

Service Manual

11.1 Removal Procedure of Indoor Unit

Step
1.Remove filter assembly
Open the front panel. Push the left filter and right filter
until they are separate from the groove on the front
panel.
Remove the left filter and right filter respectively.
2. Remove horizontal louver
Push out the axile bush on horizontal louver. Bend
the horizontal louver with hand and then separate the
horizontal louver from the crankshaft of step motor to
remove it.
3. Remove panel
① A1/B6/C2/C4 display: Screw off the 2 screws that
are locking the display board. Separate the display
board from the front panel.
② A2/A3 display: Screw off the 2 screws that are
a
locking the display board. This display can be
disassembled only after removing the front case (refer
to step 5 of disassembly).
③ A5/B2/B4/B8/C6/D2 display: Screw off the 2 screws
that are locking the display board.
Separate the panel rotation shaft from the groove fixing
b
the front panel and then removes the front panel.
Installation and Maintenance
Caution: discharge the refrigerant
completely before removal.
Procedure
Front panel
Left filter
Groove
Horizontal louver
Front panel
Panel rotation
Groove
Front
case
Right filter
Location of step motor
Axile bush
Screws