9. Remove motor and cross flow blade
Remove the screws fixing motor clamp and then
a
remove the motor clamp.
Remove the screws at the connection place of cross
flow blade and motor; lift the motor and cross flow
blade upwards to remove them.
b
Remove the bearing holder sub-assy.
Remove the screw fixing step motor and then remove
the step motor.
Installation and Maintenance
Procedure
Cross flow
Holder
sub-assy
Screws
Motor clamp
Screw
Motor
Screws
Step motor