Gree GWH07QA-K6DNC4A Service Manual page 165

Table of Contents

Advertisement

Service Manual
Step
7. Remove right side plate
Remove connection screws connecting the right side
plate with the valve support and the electric box. Then
remove the right side plate.
8. Remove the nut and gasket on the blade and then
remove the axial flow blade
Remove the nut and gasket on the blade and then
remove the axial flow blade.
9. Remove motor and motor support
Remove the tapping screws fixing the motor and
disconnect the leading wire insert of the motor. Then
remove the motor.
Remove the tapping screws fixing the motor support
and lift the motor support to remove it.
Installation and Maintenance
Procedure
gasket
nut
axial flow
motor
motor support
right side plate
163