Insulation blowing machine
Table of Contents

Advertisement

Blower By-Pass Valve: Allows the installer to decrease the amount of air being pushed down the hose
by opening the valve to vent the blower. Used most often for special wall fill capability.
Shredder Bars: The shredder bars are located just above the airlock and spin quickly to provide final
insulation processing. They are not visible.
Slide Gate: The slide gate allows insulation to fall into the airlock. The slide gate is opened fully during
typical operation. Close the gate slightly to increase the conditioning of the insulation and alter ratio of
insulation to airflow.
Gate Pin Setting: Place the pin into the desired slide gate hole to ensure the gate stays in desired
position during operation.
Airlock: The airlock transfers the insulation from the agitation system into the airstream without
coming into contact with the blowers. Insulation is discharged from the airlock into the hose.
Urethane Airlock Seals: Your FORCE 5250 includes Intec's proprietary urethane airlock
seals for long lasting effectiveness. Proper airlock sealing allows for high production
rates and high pressures for effective wall fill applications.
What's under the hood?
Slide Gate
Arm
Assembly
Shredder Bar
Box
Airlock
T: 303-833-6644
Original Language - English
That's a great question! Let's take a peek.
Gearbox
Agitator Clutch
Blower- shown with 2.5" to 4"flared intake pipe
Blower Clutch
installed. Attaches to 4" hose supplied with Fresh Air
Inlet Kit
www.inteccorp.com
Instruction Manual
|
6
12 volt battery
VANGUARD 18 hp engine with 8"
hose ring for fresh air attached
Pressure relief valve