Direct Treater Dual Installation……………………..…….Page 3- 4 Direct Treater Dual Operation…...……………………………Page 5 Direct Treater Dual Setting Functions.........Page 6 Direct Treater Dual Sub Menu Functions………………...Page 7-9 Anatomy of a Direct Treater Dual........Pages 10-12 Before You Plug In Your Machine!........Page 13 Setting Up Your Direct Treater Dual......Pages 14-18 Direct Treater Dual Shut Down Procedure....Pages 19-23...
What’s Included In The Direct Treater Dual Pretreatment Machine Package: [1] Direct Treater Dual [1] Controller Power Supply Pretreatment Machine [1] Pedal [1] Drain Tube...
Direct Treater Dual Specifications Single V-nozzle type Speed: 150~180 sheets / hour Cleaning amount: 20Sec – 150ml Size (Unit: mm) Close: 1004.44(L) X 522.10(W) X 934.64(H) Open: 1733.55 (L) X 522.10(W) X 1041.4(H) Power (Free-voltage) AC100-220V~ (50/60Hz) Working: 50W Stand by: 17W...
Direct Treater Dual Installation Positioning -Install on Flat and rigid area -Check opened size Specification page -Connect Power cable 2. Pour Pre-treatment liquid to Bottle1 or Bottle2 From left bottles Pretreatment liquid. And, third one is for Cleaner. And, last one is for waste liquid Fill Liquid 3.
Page 6
How To Install The Pedal Switch 1. Plug male connector into female connector Pretreater 2. Screw in plastic piece on male connector to lock the connector assembly 3. Push in plastic and rubber pieces for complete install...
Direct Treater Dual Operation 1. Emergency stop button. It is using It is using for emergency situation. When this button push, all electric power will be stop. For re-start, just turn this button clock wise. CAUTION After turn it clock wise, electrical power will come back.
Direct Treater Dual Sub Menu Functions Tray Sensor: When the table tray is closed, it will not display. (If you don´t want to use this sensor, you need touch this icon. That time, this icon will be change. For use again, just it need touch again).
Page 10
Settings functions: -Language: select Language -Purge: This function is for filling Pre-treatment liquid in the nozzle, after cleaning with cleaner. Open the Top cover, and then, check the Valve. Open exhaust Valve. (Vertical way is open) Then, touch the “Purge. This time, pump will work 2 sec.
Page 11
-Clean It is for clean the nozzle by cleaner(Water). Normally, this kind of pre-treatment liquid can make block the nozzle during not using period(more than 12 hours). protect this problem, we suggest to use this clean function. When push cleaning button, will first...
Anatomy of a Direct Treater Dual Pretreatment Machine Fig 1- Front View of Direct Treater dual Pretreatment Machine Fig 2- Side View of Direct Treater dual Pretreatment Machine...
Page 13
Anatomy of a Direct Treater Dual Pretreatment Machine (Cont’d) Fig.3- Under Top Hood...
Page 14
Anatomy of a Direct Treater Dual Pretreatment Machine (Cont’d) Fig.4- Back view of Direct Treater Dual Pretreatment Machine. Fig.5- Electronic components of Direct Treater Dual Pretreatment Machine.
Before You Plug-In Your Machine! 1. Locate the emergency switch at the front of the pretreatment machine. This is the small red circle with white arrows on it 2. Twist the emergency switch in a clock wise motion (as shown by arrows) and lightly pull to release it from the factory transit...
Setting Up Your Direct Treater Dual 1. With the back power switch at the OFF position, plug your power cable into the back of the pretreatment machine. Be sure to plug into a surge protector! 2. Flip the back power switch into position.
Page 17
Setting Up Your Direct Treater Dual 5. Go to the back of the printer where your pretreatment, cleaner and waste reservoirs are. knobs should horizontal to signify they are all closed off 6. Open the far left knob to point vertically. Then fill the far...
Page 18
Setting Up Your Direct Treater Dual 7. Before purging liquid into your machine for the first time, make sure drawer completely closed. If it is not closed, drawer icon will appear on the top of the screen and it will not allow you to run...
Page 19
Setting Up Your Direct Treater Dual 10. A pop-up will prompt you to switch off the cleaning fluid valve and switch on the desired pretreatment fluid valve before continuing with the purge. The far left valve should be opened and the other two valves should still be closed.
Page 20
Setting Up Your Direct Treater Dual 13. Close the blue air exhaust valve. It should now be facing horizontally. Think of this as an air pressure buildup/ release valve. line going from reservoir bottle up to the pump should now be filled sold white with pretreatment liquid.
Direct Treater Dual Shut Down Procedure Before getting started with the shut down procedure for the Direct Treater Dual, make sure the knobs for the first two left pretreatment reservoir bottles are shut and open the nob for the cleaner reservoir bottle as shown in the image above.
Page 22
Direct Treater Dual Shut Down Procedure 1. Tap on the gear icon on the top right corner of your touch screen to open your “Settings & Tools” menu. 2. Tap on the “Clean” option get started with cleaning process. 3. You will be prompted with a...
Page 23
Direct Treater Dual Shut Down Procedure 5. Check the tubes near the pump beneath the top hood. The lines should appear clear when cleaning process finishes. 6. When the cleaning process is finished, you will see a pop-up window that with two options: “Repeat”...
Page 24
Direct Treater Dual Shut Down Procedure 8. Before removing the nozzle, carefully move the spraying mechanism to the center of the track. 9. Remove the side window so that you may access the nozzle and properly remove it. 10. To properly remove the...
Page 25
Direct Treater Dual Shut Down Procedure. Upon removal, these are the parts that should be in your hand. 12. To preserve these parts, they must be left soaking overnight in cleaner liquid to loosen up waste and old pretreatment residue that can ultimately affect the functionality of these parts.
Replacing Nozzle into Spraying Mechanism 1. Before replacing the nozzle components, take the outer white plastic valve lock and face it down (shown left) as it normally does within machine. 2. Take the nozzle tip and carefully insert into the white plastic valve lock with the tip facing down as well.
Page 27
Replacing Nozzle into Spraying Mechanism 5. Lastly, insert the mesh filter with the flat top facing down (as shown left) to complete the nozzle component assembly. Iu is now ready to replace into the machine. 6. Carefully line the mesh filter with its slot on the machine and slowly push...
Official Settings Guidelines DISCLAIMER: These official settings guidelines have been established as starting points for pretreating specific garment types. Please note that all garment types, colors, brans and quality will vary in results so adjust by increasing or decreasing settings as needed until the desired result are achieved.
Need help?
Do you have a question about the Direct Treater Dual and is the answer not in the manual?
Questions and answers