Install Dkx Series Lock Strike; High Security Pedestrian - Kaba Mas DKX-10 Installation Manual

Hide thumbs Also See for DKX-10:
Table of Contents

Advertisement

Kaba Mas
4

Install DKX Series Lock Strike

NOTE: The DKX-10 Type II can be used with multiple types of doors. Reference Figure 3 as a guide to which strike is
needed.
1. Using the horizontal centerline that was scribed following the steps previously mentioned in this instruction guide mount
the appropriate strike for the door type as shown in the figure above.
2. Mount the provided drill template (115057) flush to the strike mounting surface and collinear with the previously scribed
horizontal center line and transfer the center marks onto the door.
3. Drill all holes according to the diameters listed on the template.
5
High Security Pedestrian Door Lock Installation
(DKX-10)
NOTE: Prior to continuing Deburr and clean all holes and debree.
WARNING: The electronics in the X-10 are susceptible to damage from Electro-Static Discharge (ESD). Ensure proper
grounding.
Figure 4A
1. Place the 3.5" x 5 x 1/8" backing plate against the back of the modified CDX-10.
2. Feed the cables and outer tube through the 3/8" hole in the door while positioning the DKX-10, backing plate, and Cover
Bracket (515034), oriented correctly as shown in above illustration, against the door. Insert and slightly tighten two of the
#10-32 machine screws (115052) (top and bottom, diagonal) to attach the DKX-10, backing plate and Cover Bracket
(515034) to the door.
12
Installation Guide / DKX-10 Type II
Document Number 548.0418 Rev. AX — 02/2019