Connecting The Power; Connecting The Alarm Relay; Dip Switch Setting - D-Link DIS-100E Series Quick Installation Manual

Unmanaged industrial fast ethernet switch
Hide thumbs Also See for DIS-100E Series:
Table of Contents

Advertisement

Available languages

Available languages

DANGER:

Connecting the Power

The switch can be powered using two power supplies (input range 12V – 58V). Insert the positive and
negative wires into the V+ and V- contacts on the terminal block and tighten the wire-clamp screws to
prevent the wires from being loosened.
NOTE:

Connecting the Alarm Relay

The alarm relay output contacts are in the middle of the DC terminal block connector as shown in the
following figure.
By inserting the wires and setting the DIP switch of the Port Alarm to "ON", the relay output alarm will detect
any port failures, and form a short circuit.
The alarm relay out is "Normal Open".

DIP Switch Setting

Pin No#
Status
Pin 1
ON
OFF
Pin 2
ON
OFF
Never attempt to view optical connectors that might be emitting laser energy.
Do not power up the laser product without connecting the laser to the optical fiber and
putting the cover in position, as laser outputs will emit infrared laser light at this
point.
The DC power should be connected to a properly-fused power supply.
5-Port Model
Enable the power alarm.
Disable the power alarm.
Enable broadcast storm rate limiting.
Disable broadcast storm rate limiting.