  • Page 1 O P E R A T I N G I N S T R U C T I O N S UM12 Ultrasonic sensor...
  • Page 2 This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modi‐...
  • Page 3: Table Of Contents

    Teaching in the switching point, IO-Link: Single point (DtO) or single point + 8% (DtO + 8%)..........8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12...
  • Page 4 Annex....................32 12.1 Declarations of conformity and certificates..........12.2 Licenses....................O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 5: About This Document

    … highlights useful tips and recommendations as well as information for efficient and trouble-free operation. 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12...
  • Page 6: Further Information

    Other publications related to the devices described here • Publications dealing with accessories O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 7: Safety Information

    Distance measurement is not possible below the operating range of the device. SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
  • Page 8: Modifications And Conversions

    Modifications and conversions to the device may result in unforeseeable dangers. Interrupting or modifying the device or SICK software will invalidate any warranty claims against SICK AG. This applies in particular to opening the housing, even as part of mounting and electrical installation.
  • Page 9: Ul Conformity

    NFPA79 applications only. Adapters including field wiring cables are available. For more information visit: www.sick.com/UM12 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12 Subject to change without notice...
  • Page 10: Product Description

    Operating range and limiting range Serial number Part number Type code O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 11: Type Code

    NOTE Not all combinations based on type code are possible. The available device types can be found online at www.sick.com/UM12. 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12...
  • Page 12: Setup And Dimensions

    Device ready (Green) ply voltage active IO-Link operation: (green) Ö O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 13: Temperature Compensation

    One example is thermally insulated mounting. 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12...
  • Page 14: Transport And Storage

    For storage periods of longer than 3 months, check the general condition of all components and packaging on a regular basis. O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 15: Mounting

    Rough surface: Angle ≥ 90° ± 3° between the sensor axis and object surface 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12...
  • Page 16: Electrical Installation

    The device can be grounded through the cable shield or through a blind tapped hole in the housing, for example. O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 17 This measure achieves a high degree of resistance to electromagnetic interference. 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12...
  • Page 18: Pin Assignment

    Pin assignment UM12-xxxxx1x, UM12-xxxxx5x O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 19 UM12-xxxxx6x, UM12-xxxxx7x Teach-in Figure 10: Male connector, M12, 4-pin 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12 Subject to change without notice...
  • Page 20 Device teach-in Blue Supply voltage: 0 V Black Analog output O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 21: Operation

    When the object is located within the taught-in switching window, the digital output is active. Teach in the switching window 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12 Subject to change without notice...
  • Page 22: Teaching In The Background, Io-Link: Window ± 8% (Obsb)

    N/C and N/O are adjusted. The device automatically switches to normal operation mode. O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 23: Teaching In The Analog Output

    IO-Link. To do this, connect the device to a suitable IO-Link master. A sensor-specific device description file (IODD) is required in the IO-Link master. The IODD and additional information are available at www.sick.com/UM12. 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12...
  • Page 24: Sopas Et

    To use SOPAS ET with the device, you need a device description file (SDD) for this device. You can install this within SOPAS ET using the device catalog. The device description file can be installed via the SICK web page (Internet connection required). Follow the instructions in SOPAS ET to do so.
  • Page 25: Maintenance

    ■ Carefully clean the adjoining faces with water at regular intervals. 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12 Subject to change without notice...
  • Page 26: Troubleshooting

    Troubleshooting Repairs Repair work on the device may only be performed by qualified and authorized personnel from SICK AG. Interruptions or modifications to the device by the customer will invalid‐ ate any warranty claims against SICK AG. Returns Only send in devices after consulting with SICK Service.
  • Page 27: Technical Data

    40 mm ... 240 mm 150 mm 240 mm 150 mm 240 mm 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12 Subject to change without notice...
  • Page 28: Interfaces

    At 4 mA ... 20 mA and U ≤ 20 V max. load ≤ 100 Ω. O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 29: Ambient Data

    Example object: aligned plate 500 mm x 500 mm Example object: Cylindrical bar with diameter of 10 mm 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12...
  • Page 30 Example object: Cylindrical bar with diameter of 10 mm O P E R A T I N G I N S T R U C T I O N S | UM12 8016973/1BNC/2022-02-23 | SICK Subject to change without notice...
  • Page 31: Accessories

    Accessories and, if applicable, mounting information can be found online at: • www.sick.com/UM12 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12 Subject to change without notice...
  • Page 32: Annex

    12.2 Licenses SICK uses open source software which is published by the rights holders under a free license. Among others, the following license types are used: GNU General Public License (GPL version 2, GPL version 3), GNU Lesser General Public License (LGPL), MIT license, zlib license and licenses derived from the BSD license.
  • Page 33 ANNEX 8016973/1BNC/2022-02-23 | SICK O P E R A T I N G I N S T R U C T I O N S | UM12 Subject to change without notice...
  • Page 34 E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...

Table of Contents