SICK UC12 Operating Instructions Manual

SICK UC12 Operating Instructions Manual

Ultrasonic sensor
Hide thumbs Also See for UC12:

Advertisement

O P E R A T I N G I N S T R U C T I O N S
UC12
Ultrasonic sensor

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UC12 and is the answer not in the manual?

Questions and answers

Summary of Contents for SICK UC12

  • Page 1 O P E R A T I N G I N S T R U C T I O N S UC12 Ultrasonic sensor...
  • Page 2 Original document This document is an original document of SICK AG. O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK Subject to change without notice...
  • Page 3: Table Of Contents

    Teaching in the background, IO-Link: Window ± 8% (ObSB). 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 4 Annex....................31 12.1 Declarations of conformity and certificates..........12.2 Licenses....................O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK Subject to change without notice...
  • Page 5: About This Document

    … highlights useful tips and recommendations as well as information for efficient and trouble-free operation. 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 6: Further Information

    Other publications related to the devices described here • Publications dealing with accessories O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK Subject to change without notice...
  • Page 7: Safety Information

    Use of unauthorized spare parts, consumables, and accessories ■ 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 8: Modifications And Conversions

    Safety requirements relating to work on electrical systems must be complied with. ■ O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK Subject to change without notice...
  • Page 9 Install the grounding for the product and the system in accordance with national ■ and regional regulations. 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 10: Product Description

    Data Matrix code with product data Type code Part number Serial number O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK Subject to change without notice...
  • Page 11: Type Code

    Not all combinations based on type code are possible. The available device types can be found online at www.sick.com/UC12. 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 12: Setup And Dimensions

    • The digital output is deactivated for approx. 30 minutes. O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK Subject to change without notice...
  • Page 13 One example is thermally insulated mounting. 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 14: Transport And Storage

    For storage periods of longer than 3 months, check the general condition of all components and packaging on a regular basis. O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK...
  • Page 15: Mounting

    Rough surface: Angle ≥ 90° ± 3° between the sensor axis and object surface 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 16: Electrical Installation

    The device can be grounded through the cable shield or through a blind tapped hole in the housing, for example. O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK...
  • Page 17 This measure achieves a high degree of resistance to electromagnetic interference. 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 18: Pin Assignment

    Teach-in via digital output: The first output is complementary to the second output. UC12-xxxx1, UC12-xxxx5 O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK...
  • Page 19 Black Digital input / inverted digital output / IO-Link 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 20: Operation

    The switching point is taught in. The device automatically switches to normal operation mode. O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK...
  • Page 21: Teaching In The Switching Window, Io-Link: Window (Window Mode)

    + 8 % – 8 % Figure 9: UC12-xxxxE 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 22: Resetting The Device To Factory Settings

    SOPAS ET can be used for device types that come with an IO-Link interface. O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK...
  • Page 23 A connection to the device is established via the communication interface. The connec‐ tion must be activated for data transmission (online). 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 24: Maintenance

    ■ Carefully clean the adjoining faces with water at regular intervals. O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK Subject to change without notice...
  • Page 25: Troubleshooting

    Separate the recyclable materials by type and place them in recycling containers. ■ 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 26: Technical Data

    30 ms Switching frequency 25 Hz Output time 8 ms O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK Subject to change without notice...
  • Page 27: Interfaces

    –25 °C ... +70 °C temperature Storage temperature –40 °C ... +85 °C 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 28: Detection Ranges

    Detection range dependent on reflection properties, size, and alignment of the object Limiting range O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK...
  • Page 29 Example object: cylindrical bar with a diameter of 10 mm 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 30: Accessories

    Accessories and, if applicable, mounting information can be found online at: • www.sick.com/UC12 O P E R A T I N G I N S T R U C T I O N S | UC12 8010984/1BNB/2022-05-12 | SICK Subject to change without notice...
  • Page 31: Annex

    Printed copies of the license texts are also available on request. 8010984/1BNB/2022-05-12 | SICK O P E R A T I N G I N S T R U C T I O N S | UC12 Subject to change without notice...
  • Page 32 E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...

Table of Contents