Main Menu Summary - Bosch HPC 400 Operating Instructions Manual

User interface
Table of Contents

Advertisement

14 | Working with the main menu
5.1

Main menu summary

If two or more heating/cooling circuits are installed in the
system, an additional selection must be made in some menus:
Menu
Purpose of the menu
Heating/Cooling
Change the operating mode, room temperatures and time program for the heating system
permanently.
Operating mode
Select the heating operating mode, based on a time program or optimised.
Temperature
Set the required room temperatures that can be assigned to the periods in the time
settings
program, e.g. with heating and setback mode or cooling mode.
Time program
Switch between heating and setback mode at defined times of day and on defined days of
the week (automatic mode). Separate time programs can be used for DHW and circulation.
Heating circuits and time programs are renamed in this menu.
Sum./wint.
Switch automatically between summer mode (heating off or cooling), winter mode (heating
changeover
on) or automatic mode (sometimes subject to outside temperature).
DHW alternating
If DHW alternating operation is activated, the heat generated by the heat pump is used
operation
alternately for heating and DHW heating.
Priority heating
Heating circuit 1 determines how the system behaves. If there is no heat requirement for
circuit 1
heating circuit 1, no heat requirements for other circuits are handled either.
DHW
Change the water temperatures and time program for DHW heating permanently.
Operating mode
Select the DHW heating operating mode, e.g. based on a time program or always on.
Time program
Switch between DHW, reduced DHW heating and no DHW heating operating modes at
defined times of day and on defined days of the week (automatic mode).
Extra hot water
Change the temperature and duration of the extra DHW function.
Thermal disinfection Heat up DHW to kill off pathogens.
DHW alternating
If DHW alternating operation is activated, the heat generated by the heat pump is used
operation
alternately for heating and DHW heating.
1)
Circulation
Set time program for DHW circulation so that DHW is available without delay at the draw-off
points.
Pool
Settings for operating a heated swimming pool.
Device
Settings for operating an auxiliary heater (electric/gas/oil/solid fuel).
Time program
The time program for the auxiliary heater specifies the periods during which additional heat
additional heat
can be generated by the auxiliary heater.
Low-noise operation Settings for reducing noise emissions from the heat pump
Holiday
Settings for operating the system during prolonged periods of absence (holiday program).
Hybrid system
Set the energy/price ratio.
Smart Grid
Use energy from the "smart grid" for heating or DHW heating.
Heating
Temperature setting for forced or selectable peak
DHW
Switch selectable peak on and off
PV system
Use energy generated by the photovoltaic system for heating or DHW heating.
Settings
Change general settings such as time, date, display contrast, etc. or restore settings saved
by the contractor.
Table 9
Main menu summary
1) Not available if Sweden or Finland is set as the country (for the contractor only).
6 720 817 986 (2015/07)
CLIMATE CONTROL SYSTEMS
▶ Turn the selector to select the heating circuit for which the
settings are being changed.
▶ Press the selector to display the menu.