Carrier 62MB Installation, Start-Up And Service Instructions Manual page 50

Energy recovery ventilators
Table of Contents

Advertisement

UNIT SIZE
VOLTAGE
ERV WHEEL
62M
(V-Ph-Hz)
208/230-3-60
640
460-3-60
575-3-60
208/230-3-60
750
460-3-60
575-3-60
208/230-3-60
950
460-3-60
575-3-60
LEGEND
ERV
— Energy Recovery Ventilator
FLA
— Full Load Amps
Hp
— Horsepower
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
NEC
— National Electric Code
N/A
— Not Applicable
*Fused disconnect only.
†Exhaust and supply fan motors are 230-1-60.
Table 2 — Electrical Data Without VAV Option (cont)
EXHAUST AND SUPPLY MOTOR
FLA
NEC - FLA
22
1.2
11
9
2.5
22
1.2
11
1.4
9
2.5
30.8
1.2
14
1.4
11
POWER SUPPLY
HEATER
SIZE
(kW)
Hp
FLA
MCA
45.53
56.50
8
65.64
81.63
10
70.66
87.91
15
83.23 103.62 110.40
22.82
29.00
8
32.87
41.57
10
35.38
44.71
15
41.66
52.56
18.65
24.00
8
26.69
34.05
10
28.70
36.57
15
33.73
42.85
7.5
46.83
58.13
10
71.96
89.54
15
84.53 105.25 111.70
20
97.09 120.95 124.26
23.36
29.00
10
35.93
44.71
15
42.21
52.56
20
48.49
60.41
19.53
24.25
10
29.58
36.82
15
34.61
43.10
20
39.64
49.38
64.46
80.13 102.60
10
92.25 114.86 130.39
15
106.15 132.23 144.29
20
120.04 149.60 158.18
29.36
36.50
10
41.93
52.21
10
15
48.21
60.06
20
54.49
67.91
23.53
29.25
10
33.58
41.82
15
38.61
48.10
20
43.64
54.38
50
DISCONNECT
PRE-HEATER
(Optional)
(Optional)
Fuse Size†
FLA
Amps
MOCP
72.70
100
92.81
20.11
97.83
25.13
200
37.70
36.95
60
47.00
10.05
49.52
12.57
60
55.80
18.85
80
30.45
40
38.49
8.04
40.50
10.05
60
45.53
15.08
74.00
100
99.13
25.13
37.70
200
50.26
36.95
60
49.52
12.57
55.80
18.85
80
62.08
25.13
80
30.65
40
40.70
10.05
45.73
15.08
60
50.76
20.11
27.79
200
41.69
55.58
46.70
60
59.27
12.57
80
65.55
18.85
80
71.83
25.13
100
37.15
60
47.20
10.05
52.23
15.08
80
57.26
20.11
Amps
70
90
110
35
45
50
30
35
40
45
70
90
110
35
45
50
60
30
40
45
50
100
125
N/A
45
50
60
70
35
45
50

Advertisement

Table of Contents
loading

This manual is also suitable for:

62mc62md62meMe040-950

Table of Contents

Save PDF