Pavone Systems DAT 200 Technical Manual page 29

Serial and profinet/ethernet ip weighing indicator/transmitter
Table of Contents

Advertisement

TABLE B: COMMAND REGISTER
Register value
COMMAND REGISTER FUNCTION
0x0001
Semiautomatic zero
0x0002
Self-calibration
0x0003
Peak reset
0x0004
Switch in Gross mode
0x0005
Switch in Net mode
0x0006
Switch in Peak mode
0x0010
Calibration of the weight zero
0x0011
Calibration of the full weight scale
0x0020
Saving the data in the permanent memory
0x7FFF
Direct access memory
Warning: the value entered in the Command Register is always active until you write again 0x0000.
Address
Data stored in memory with command 0x0020
41001-41002 Load cells capacity
41003
Load cells sensitivity
41004
Weight division value
41101
Weight filter factor
41102
Weight stability factor
41103-41104 Auto-zero SET POINT
41105
Zero tracking factor
41106
Zero band
41107
Weight Delta
TABLE C: DIVISION VALUE
Register
0
value
Division
0.0001 0.0002 0.0005 0.001
value
Register
9
value
Division
0.1
value
1
2
3
10
11
12
0.2
0.5
1
DATA REGISTER FUNCTION
4
5
6
0.002
0.005
0.01
13
14
15
2
5
10
-
-
-
-
-
-
-
sample weight
-
7
8
0.02
0.05
16
17
20
50
Page 27