LIST OF THE MODBUS PROTOCOL HOLDING REGISTERS
Address Holding Register
40001 Status Register
40002 Gross weight (MSB)
40003 Gross weight (LSB)
40004 Net weight (MSB)
40005 Net weight (LSB)
40006 Peak (MSB)
40007 Peak (LSB)
40501 Data Register (MSB)
40502 Data Register (LSB)
40503 Command Register
41001 Load cell capacity (MSB)
41002 Load cell capacity (LSB)
41003 Load cell Sensitivity
41004 Weight division value
41101 Weight filter factor
41102 Weight stability factor
41103 Auto-zero at power ON
41104 Auto-zero at power ON
41105 Zero tracking factor
41106 Zero band
41107 Weight Delta
42000 Monitor register
42100 Monitor register
TABLE A: STATUS REGISTER
BIT
15
Description
Not used
BIT
7
Not
Description
calibrated
WARNING: bits 13, 12, 11 and 10 are always 0.
Page 26
R/W Format Notes
R
INT
R
INT
R
INT
R
INT
R
INT
R
INT
R
INT
W
INT
W
INT
W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
W
INT
R
INT
14
13
Not used
0
6
5
Wrong
Over-load
weight
See Table A.
Writing before or with the same query of Command
Register.
Writing before or with the same query of Command
Register.
See Table B page 27.
See Table C page 27.
The programmed value is automatically copied to
Monitor Register (42100).
12
11
0
0
4
3
Tare
Under-load
entered
10
9
0
Memory Flag Not used
2
1
Stable
Zero band
weight
8
0
Center of
Zero

Advertisement

Table of Contents
loading

Table of Contents