Viewing, Zeroing The Weight And Autotare - Pavone Systems DAT 200 Technical Manual

Serial and profinet/ethernet ip weighing indicator/transmitter
Table of Contents

Advertisement

VIEWING, ZEROING THE WEIGHT AND AUTO TARE
When the instrument is switched ON, the display shows the current net weight.
8
3
3
5
6
2
5
0
8
-
- -
3
-
-
-
6
-
-
-
5
-
-
3 sec.
1
6
2
5
0
3 sec.
Page 10
VIEWING THE NET WEIGHT/GROSS WEIGHT
Press the key
to toggle between the net weight to gross weight
s
and vice versa. The value displayed is reported by the LED 1 (lit:
net weight). If you have not entered the tare, the net weight is equal
to the gross weight.
In case of negative weight, it is displayed the minus sign before the
most significant digit. In case of negative weight greater than 9999,
the minus sign is displayed alternatively with the most significant digit.
NUMERICAL VIEWING/BAR-GRAPH OF THE GROSS WEIGHT
Press the key
to toggle from numerical display of the weight to
u
the graphical representation of the gross weight and vice versa.
The resolution is limited to 15 divisions and therefore each segment
represents 1/15 of full scale.
The bar-graph display is indicated by both LEDs flashing.
ZEROING THE WEIGHT
This operation is performed to correct small movements of the zero
of the scale. To perform the reset function, it is necessary to switch
the display to gross weight.
Press u key for 3 seconds to zeroing gross weight.
The gross weight reset command does not run under the following
conditions:
Unstable weight.
Gross weight greater (positive or negative) than the 0BAND value set.
If you previously performed the autotare function, this is automatically
delayed. When the instrument is switched off, it is restored the value
of Zero made during calibration.
AUTOMATIC TARE
To perform the auto-tare function, it is necessary to switch the display
to Net weight (LED 1 on).
Press u key for 3 seconds to to perform Autotare function. Led 2
switched on. The automatic tare command does not run under the
following conditions:
Unstable weight.
Negative gross weight.
Gross weight greater than the maximum capacity.
If the automatic tare is performed with gross weight = 0, the display
shows again gross weight (Led 1 switched off).

Advertisement

Table of Contents
loading

Table of Contents