MIN 3K-11.4K TL-XH-US
&
Commissioning Guide

Advertisement

loading
Need help?

Need help?

Do you have a question about the MIN 3 K-11.4K TL-XH-US and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Growatt MIN 3 K-11.4K TL-XH-US

  • Page 1 Growatt New Energy Download MIN 3K-11.4K TL-XH-US Manual & Commissioning Guide Growatt USA,Inc 9227 Reseda Blvd,#435 Northridge,CA 91324,USA. 1(866) 686-0298 usaservice@ginverter.com www.growatt-america.com GR-UM-251-A-00...
  • Page 2 List 1 Power on the system 1.1 Energy Management System Introduction 1.2 Check System Installation & Power On 2 ShineTools APP Setup 2.1 APP Download 2.2 APP Introduction 2.3 Connecting to Local Wi-Fi Network 3 Grid Code Mapping Table 4 Wi-Fi Network Configuration 5 Energy Management System 5.1 Management System Mode Introduction...
  • Page 3: Power On The System

    Power on the system 1.1.1 System Configuration Contains 1.1 Energy Management System Introduction Energy Storage System / Off-Grid System. MIN 3K-11.4KTL-XH-US energy storage system diagram is shown in the figure below: Ø MIN 3-11.4KTL-XH-US inverter.   Ø ARO battery(s). Ø ATS.
  • Page 4 1.2.1 Installation and Wiring of Electric Meter SM-US-200 a) Meter Mounting Ø The meter should be mounted in a Power Distribution Box. Ø Mount the meter on a 35mm DIN rail. Fig 1.7 b) CT Installation Install the two CTs with the Arrow pointing to the LOAD. Ø...
  • Page 5 ShineTools APP Setup 2.3 Connecting to Local Wi-Fi Network 2.1 APP Download The steps for using APP are as follows: There are two ways to download the ShineTools APP: Setup local Wi-Fi to communicate with the inverter a) Scan the QR code 2.Enter the default 1.Login interface 3.Tap in Direct WiFi...
  • Page 6 2.4 Local Commissioning Main Interface Introduction 7. Tap in Next 8. Tap in Auto refresh The main interface of local commissioning consists of three parts: Now this APP has been connected to the built-in Internal information Power generation WIFI of the inverter. Fault warning message viewing and parameter information...
  • Page 7: Wi-Fi Network Configuration

    Wi-Fi Network Configuration 4 Grid Code Mapping Table First time install the inverter, the inverter needs to be configured to connect to the home The factory Default grid mode of the inverter is IEEE1547-240, which can adapt to the Wi-Fi to ensure the remote monitoring. most power grids.
  • Page 8: Energy Management System

    5 Energy Management System Notice: First time install the energy storage system, charge the battery for at least 1 hours Maximum self- Use PV production for self-consumption, then charge/discharge or up to 60% SOC before powering off the system. This action will keep up the battery consumption battery as needed to maximize self-consumption power to avoid running out while waiting for PTO.
  • Page 9 5.2.1 Power Sensor Setting 5.2.2 AC Charging Setting If an electric meter is installed in the system, please set. Factory Default is Disabled. The AC charging is used to set whether to allow charging the battery from the Grid. Note: Power Sensor: iOS = Electric meter Factory Default is Disabled.
  • Page 10 5.2.3 EMS Mode Setting: 4.Select the Quarter to be For Backup ONLY scenarios ,it's done on No. 5 set, Four quarters can be If an ARO battery is installed in the system, you need to set the energy storage mode. 4.Select the TIME to be set 5.Select the YEAR to be set Factory Default is Maximum Self-Consumption.
  • Page 11: Troubleshooting

    6 Battery Life Maintenance Commissioning Error Code 7 Troubleshooting (Important) Enter the local commissioning home page, and view the fault and alarm information on a) TUnplug Battery power, Battery Communication cables and turn OFF battery modules the main interface if there are exist after installation. The fault and alarm code on the power (Check battery quick installation guide for the detail) .
  • Page 12 ShinePhone App. restored, contact manufacturer. 8.1 Register an Account PV panel insulation a) Log in to our monitoring website http://server-us.growatt.com and click Register an Error 203 PV Isolation Low 1. Check PV panel and wiring. problem Account.
  • Page 13 b) When you have completed these steps, you will be able to view the inverter system c) Fill in the appropriate power plant information in order to complete the power plant remotely through the ShinePhone APP and through any browser. creation.
  • Page 14 9 Shinephone Introduction 9.1 APP Download Setup local Wi-Fi to communicate with the inverter 2. Fill the register info, There are two ways to download the ShinePhone APP: Notice: For Installer code: c) Scan the QR code ask for your installer, once 1.Tap in Register you fill your installer code, 3.Fill the plant info...
  • Page 15 7. The Plant page display 8.tap in “+” to add the the list of plants under the Plant. plant account Growatt USA,Inc 9227 Reseda Blvd,#435 Northridge,CA 91324,USA. 1(866) 686-0298 usaservice@ginverter.com www.growatt-america.com...