Download Print this page
Stannah STAIRISER SR User Handbook Manual
Hide thumbs Also See for STAIRISER SR:

Advertisement

Quick Links

STAIRISER SR
USER HANDBOOK
IMPORTANT
Before using your Stannah Stairiser platform lift, please
ensure that you read and familiarise yourself with these
instructions.

Advertisement

loading
Need help?

Need help?

Do you have a question about the STAIRISER SR and is the answer not in the manual?

Questions and answers

Summary of Contents for Stannah STAIRISER SR

  • Page 1 STAIRISER SR USER HANDBOOK IMPORTANT Before using your Stannah Stairiser platform lift, please ensure that you read and familiarise yourself with these instructions.
  • Page 2: Table Of Contents

    C O N T E N T S Introduction Safety Instructions General Layout Operating Instructions Emergency Operations General Stairiser Care Procedures Trouble Shooting Guide Warranty Promise NOTE: Whilst every effort has been made to ensure the clarity and accuracy of this hand book, we cannot be held responsible for any damage or injury resulting in negligence or misuse of this Stairiser.
  • Page 3: Introduction

    A Service Log Card supplied by the Service Branch will be completed after each service visit. Failure to ensure servicing is carried out could lead to unreliable or unsafe operation. For all enquiries regarding servicing, please contact your local Stannah Service Branch. For your records: For your records:...
  • Page 4 Stannah Lift Services. Maintenance is carried out to ensure the lift runs efficiently and safely.
  • Page 5 I N T R O D U C T I O N PRODUCT LIFE EXPECTANCY Product life expectancy depends largely on the environment, usage and the undertaking of proper scheduled maintenance. Our lift products are designed and life tested for a full life cycle of 10 years without major intervention.
  • Page 6: Safety Instructions

    S A F E T Y I N S T R U C T I O N S • The lift must not be overloaded. The maximum capacity of the lift is indicated on the front face of the carriage. Safe working load: 250kg wheelchair &...
  • Page 7: General Layout

    G E N E R A L L AYO U T 1. Key switch 2. Emergency STOP 3. Ramps 4. Barriers, liftable 5. Carriage cover 6. Directional control 7. Folding seat (option) 8. Main control button at the carriage side 9.
  • Page 8 G E N E R A L L AYO U T Wall control Recharger Carriage Upper stop position Lower stop position Intermediate stop position (n/a) Upper railway tube Lower railway tube Overspeed governor Battery Charge System Battery Charge System Battery Charge System Battery Charge System The motor of the stairiser is powered by batteries, which are reloaded by a recharger.
  • Page 9 Landing Controls Landing Controls The Stairiser SR is equipped with landing controls that communicate via radio with the carriage. With these controls, the lift can be called and sent when the platform is closed. In the case of automatic platform the platform also can be opened and closed with the con- trols.
  • Page 10: Operating Instructions

    O P E R AT I N G I N S T R U C T I O N S The Stairiser SR is easy to use. The technical control of the lift is entirely adapted to the abil- ities of physically handicapped persons. Please refer to the general layout on the previous pages for a better understanding of the lift.
  • Page 11 O P E R AT I N G I N S T R U C T I O N S Wall Controls Wall Controls Wall Controls Wall Controls All automatic platform lifts are equipped with wall controls which allow control from either end of the staircase and allow for the folding down or up the platform.
  • Page 12 O P E R AT I N G I N S T R U C T I O N S Driving/Moving onto the Platform Driving/Moving onto the Platform Driving/Moving onto the Platform Driving/Moving onto the Platform You can move onto the platform after you have opened the platform and the barrier in ac- cordance with the former chapter.
  • Page 13 O P E R AT I N G I N S T R U C T I O N S Travelling Travelling Image 4 Image 4 Travelling Travelling Image 4 Image 4 The carriage control on the sidewall consists of a directional control on spiral cable, a key switch and an emergency stop (image 4).
  • Page 14 O P E R AT I N G I N S T R U C T I O N S Always maintain a clear view of the Image 5 Image 5 Image 5 Image 5 lift on the stairs! If there is danger, stop the lift by releasing the control button.
  • Page 15 O P E R AT I N G I N S T R U C T I O N S Leaving the platform Leaving the platform Image 6 Image 6 Leaving the platform Leaving the platform Image 6 Image 6 The stairiser has been designed to stop in the Lift up correct position at each station.
  • Page 16: Emergency Operations

    E M E R G E N C Y O P E R AT I O N If it’s necessary to evacuate a user from the lift due to either lift or power failure, the proce- dures described here should be followed. A different process is needed, dependant on where the platform has stopped: Case 1 Case 1...
  • Page 17 E M E R G E N C Y O P E R AT I O N Case 2 Case 2: The occupied platform is not close to a stop position : The occupied platform is not close to a stop position Case 2 Case 2 : The occupied platform is not close to a stop position...
  • Page 18 E M E R G E N C Y O P E R AT I O N Emergency Unclamping of Barrier Emergency Unclamping of Barrier Emergency Unclamping of Barrier Emergency Unclamping of Barrier For unclamping a barrier somewhere out of a station, press the lever located at the back of the carriage.
  • Page 19: General Stairiser Care Procedures

    Keep the access free to the drive and to the main power switch. When cleaning the stairiser use a soft cloth and soapy water. All further maintenance work is only allowed to be done by Stannah Lift Services Ltd or any of our authorised partners.
  • Page 20: Trouble Shooting Guide

    T R O U B L E S H O OT I N G G U I D E For safety reasons, the Stairiser SR is equipped with several electrical and mechanical lock- ing devices. The stairiser will not work if any of these devices are tripped or if the order of events is incorrect.
  • Page 21 T R O U B L E S H O OT I N G G U I D E...
  • Page 22 T R O U B L E S H O OT I N G G U I D E...
  • Page 23: Warranty Promise

    Stannah reserve the right to change the terms of any warranty provided subject to any such change being notified to the beneficiary in writing.
  • Page 24 We are continually developing and improving the Stairiser range and we therefore reserve the right to alter or amend the specification without prior notice. Stannah Lifts Ltd Telephone: 01264 339090 Telephone: 01264 339090 Telephone: 01264 339090 Telephone: 01264 339090 Email: contact@stannah.co.uk...