Advertisement

Quick Links

STAIRISER CR
USER HANDBOOK
IMPORTANT
Before using your Stannah Stairiser platform stairlift, please
ensure that you read and familiarise yourself with these
instructions.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STAIRISER CR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Stannah STAIRISER CR

  • Page 1 STAIRISER CR USER HANDBOOK IMPORTANT Before using your Stannah Stairiser platform stairlift, please ensure that you read and familiarise yourself with these instructions.
  • Page 2: Table Of Contents

    C O N T E N T S Introduction Key Symbols In Handbook Intended Use General Layout Compact Motor Box External Call Stations Operation Emergency Release Maintenance Troubleshooting Error Table Warranty Promise Service Branches NOTE Whilst every has been made to ensure the clarity and accuracy of this hand- book, we cannot be held responsible for any damage or injury resulting in negligence or misuse of this platform stairlift.
  • Page 3: Introduction

    Failure to ensure servicing is carried out could lead to unreliable or unsafe operation. For all enquiries regarding servicing, please contact your local Stannah Service Office at the address given in this booklet. A Service Log Card supplied by the Service Office will be completed after each service visit.
  • Page 4: Key Symbols In Handbook

    K E Y S Y M B O L S I N H A N D B O O K The following signs stress important areas: Pay attention to all paragraphs marked with this sign. These paragraphs contain important hints that will ensure smooth operation of the lift. WARNING! Important safety advice! Observing these instructions greatly reduces the possibility of hazardous situations.
  • Page 5: Intended Use

    Safe working load: 225 kg (496 lb) for the wheelchair platform. 100 kg (286 lb) for fold down seat. The Stairiser CR must only be used for the transport of persons in wheelchairs or sitting • on the optional fold down seat.
  • Page 6: General Layout

    G E N E R A L L AYO U T WARNING - Before using your lift, please read and familiarise yourself with these instructions Wall control Horizontal railway Drive box (small or big) Upper railway tube Carriage Lower railway tube Upper stop position Overspeed governor Intermediate stop position...
  • Page 7 G E N E R A L L AYO U T Carriage with platform for wheelchairs Handset with direction buttons, audio alarm and stop switch (key switch optional) Display Access ramps Barrier arms Sidewall covers Directional control (joystick) Folding seat Carriage with seat performance Directional control Armrest...
  • Page 8: Compact Motor Box

    C O M PAC T M OTO R B OX Upper ultimate limit switch Main power switch Drive unit control board Frequency inverter Motor Emergency hand wheel...
  • Page 9: External Call Stations

    E X T E R N A L C A L L S TAT I O N S All Stairiser CR installations are equipped with calling stations, with which you can call and send the lift. Call stations are located in the area of the upper and lower landing position.
  • Page 10: Operation

    O P E R AT I O N Main power switch The main power switch connects the lift to the power supply system. For use of the lift, first turn on the main power switch. By switching off the main power switch, the stairlift can be isolated from the circuit.
  • Page 11 O P E R AT I O N Travelling Key switch Emergency stop button Barriers Carriage Directional controls (on device and hand held) When the passenger has moved onto the platform in accordance with the “Driving/Moving onto the platform” instructions, the carriage can be set in motion by pressing the “up”...
  • Page 12: Emergency Release

    E M E R G E N C Y R E L E A S E If it necessary to evacuate a user from the lift due to either lift or power failure, the procedures described here should be followed. A different process is needed, dependant on where the platform has stopped: Case 1 The occupied platform is near a stop position.
  • Page 13 E M E R G E N C Y R E L E A S E Case 2 The occupied platform is not close to a stop position. The position of the main power switch, the hand lever for brake release and the hand wheel is indicated on page 8.
  • Page 14 E M E R G E N C Y R E L E A S E Emergency unclamping of barriers For unclamping a barrier somewhere out of a station, press the lever located at the back of the carriage. The position of this lever is shown in detail in Illustrations below.
  • Page 15: Maintenance

    M A I N T E N A N C E It is recommended that a service contract is made with Stannah Lifts Services to ensure the lift is regularly serviced. Check-up and care Check the following points at regular intervals: The carriage must not start travelling until the barrier is folded down and the ramp is turned down to the appropriate position.
  • Page 16: Troubleshooting

    Troubleshooting For safety reasons, the Stairiser CR is equipped with several electrical and mechanical locking devices. The Stairiser CR will not work if any of these devices are tripped or if the order of events is incorrect. By following the instructions provided in the ensuing paragraphs, the user will be able to determine the reason for breakdown.
  • Page 17 T R O U B L E S H O OT I N G Possible Errors If during the operation of the lift an error is occurring, it will be displayed as an error code on the 7 segment display on the control boards as well as on the LCD display. If there is no error the display shows Omega as in the picture on the left.
  • Page 18: Error Table

    T R O U B L E S H O OT I N G Error table In the following table all error codes are listed. The error code is shown on the LCD display. An error can be acknowledged by the Display menu, via the button S1 on the platform control or by switching the main power supply on and off.
  • Page 19 T R O U B L E S H O OT I N G Name Number Device reaction Possible reason Wrong impulses 7 (7) Running slower If the counted impulses in the landing than normal in intermediate stations differ too much from the landing station saved impulses.
  • Page 20 T R O U B L E S H O OT I N G Name Number Device reaction Possible reason Overload 12 (C) Platform will If the platform is overloaded and the travel to the next overload switch SU gives a signal to landing station, the controller.
  • Page 21 T R O U B L E S H O OT I N G Name Number Device reaction Possible reason Feedback from 20 (5.) Platform will trav- One of the main drive contactors or main contactors el to the next the safety circuit relay KSK has not landing station, been released after the platform...
  • Page 22: Warranty Promise

    Stannah reserve the right to change the terms of any warranty provided subject to any such change being notified to the beneficiary in writing.
  • Page 23: Service Branches

    S TA N N A H S E R V I C E B R A N C H E S CONTACT STANNAH LIFT SERVICES LIMITED AT: SCOTLAND SOUTH MIDLANDS & NATIONAL CONTRACTS 45 Carlyle Avenue, HOME COUNTIES No.1 Ravensquay Business...
  • Page 24 We are continually developing and improving the Stairiser range and we therefore reserve the right to alter or amend the specification without prior notice. Stannah Lifts Ltd Anton Mill, Andover, Hampshire SP10 2NX Telephone: 01264 339090 www.stannahlifts.co.uk...