https://appliancetechmanuals.com
Lower O ven Section
T H E CON VECT ION FAN MOTOR
Refer to Page 42 to access the convection fan
motor.
1.
W ith no power applied, disconnect the motor
wire connectors from their terminals.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter leads to the motor ter-
minals. The meter should indicate 12
4.
If the reading is not correct, remove and
replace the convection fan motor.
Convection Fan Motor
T H E LAMP T RAN SFORMER
Refer to Pages 56 to access the lamp transformer.
1.
W ith no power applied, remove the wires
from the terminals of the lamp transformer.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter leads to the primary
terminals. The meter should indicate 9
Ω
.
4.
Touch the ohmmeter leads to the secondary
terminals. The meter should indicate 2
5.
If the readings are not correct, remove and
replace the lamp transformer.
Page 62
SMW O ven Service Manual
10
Secondary
Winding
6
5
Primary
Winding
1
Ω
.
Ω
.