PEAK COMMUNICATIONS P7001R Installation And Operating Handbook page 33

Table of Contents

Advertisement

Instruction 46 (Redundancy Status Request Reply):
Message
Byte No.
1
2
3
4
5
6
7
8
9
10
11
12
13
Page 33
Set Value /
(example)
02
?
?
46
('1')
('M')
('0')
('A')
('1')
('A')
('1')
?
03
P7001R & P7002R Series Converters
Length
Description
(bytes)
1
STX
1
No of bytes in message
1
Address
1
Message instruction
1
Redundancy Type Configuration
'1' = 1 for 1
'2' = 1 for 2
'N' = 1 for N
1
Redundancy Manual Mode
'M' = Manual
'A' = Auto
'X' = Units setup as 1 for 1 type
1
Online Status
'0' = Offline '1' = Online
1
Unit Identifier
'A' or 'B' when in 1 or 1 configuration
'A' or 'B' or 'S' when in 1 or 2 configuration
1
Unit Priority
'X' when in 1 for 1 configuration or if units
are selected as standby
'1' or '2' when in 1 for 2 configuration
1
Unit Online
'A' or 'B' when in 1 for 1 configuration.
'A' or 'B' or 'S' when in 1 for 2 configuration
and the unit selected as standby
otherwise 'X'
'@' means no redundant controller
attached, unit online not known.
1
Coax Switch Position
'1' or '2'
'@' means no redundant controller attached
, position not known
1
Checksum
1
ETX