PEAK COMMUNICATIONS P7001R Installation And Operating Handbook page 31

Table of Contents

Advertisement

The unit MUST be in remote mode to allow reconfiguration of parameters via the
remote control.
Instruction 40 (Unit Status Request):
Message
Byte No.
1
2
3
4
5
6
Instruction 41 (Unit Status Request Reply):
Message
Byte No.
1
2
3
4
5
('01234' = Serial No 01234)
32
37
44
45
46
47
48
49
50
67
68
69
70
71
Page 31
Set Value /
(example)
02
?
?
40
?
03
Set Value /
(example)
02
?
?
41
('
P7001R')
('0112.34')
('0' = OK)
('0')
('0')
('0')
('0')
('0')
('23/12/02 12:34:56')
('0')
('0')
('0')
?
03
P7001R & P7002R Series Converters
Length
Description
(bytes)
1
STX
1
No of bytes in message
1
Address
1
Message instruction
1
Checksum
1
ETX
Length
Description
(bytes)
1
STX
1
No of bytes in message
1
Address
1
Message instruction
27
Type of unit this is: P7001R, P7002R
5
Serial Number
7
Software Version Number
1
Summary Alarm OK/FAULT
'0' = OK '1' = FAULT
1
Primary DC voltage out of range fault
'0' = OK '1' = FAULT
1
Temperature out of range fault
'0' = OK '1' = FAULT
1
External Reference fault
'0' = OK '1' = FAULT
1
Crystal fault
'0' = OK '1' = FAULT
1
Coax Switch fault
'0' = OK '1' = FAULT
17
OK Since time/date string.
If the SNTP time is not valid then the string
is "OK"
If there is a fault with this units section then
the string is "NOT OK".
1
1:1 Status
'0' = Offline '1' = Online
1
Remote mode
'0' = Local '1' = Remote
1
External Reference
'0' = Off '1' = On
1
Checksum
1
ETX