2.2.1 Mounting

The product can be mounted using the multiple mounting holes supplied on the
bracket. Alternatively the mounting brackets may be removed and the unit mounted
using the 4 hole on the base of the unit, hoever the correct length of screw must be
used to prevent damage to the unit

2.2.2 Cooling

Unit must be mounted in a position to minimise solar gain and provide cooling via the
mounting bracket.
2.3 Prime Power Supply & Connection
24VDC to 36VDC required to power these units.

2.3.1 Fuses

The equipment is provided with short circuit fuse protection. The fuse size is 5 x 20
mm, rated at 1A and is replaceable via the fuse holder on the front face of the units.
Page 17