Ethernet Settings Status Message
This message is sent to the unit, when the host computer wishes to query the Ethernet settings. These
Ethernet messages have an Instruction number as well as a subinstruction.
Instruction 4, Subinstruction 1 (Ethernet Status Request):
Message
Byte No.
1
2
3
4
5
6
7
The unit then responds with the following message:
Instruction 5, Subinstruction 1 (Ethernet Status Reply):
Message
Byte No.
1
2
3
4
5
6
7
8
23
24
39
40
55
56
57
58
73
74
Page 24
Set Value /
(example)
02
7
?
4
'1'
?
03
Set Value /
(example)
02
7
?
5
'1'
'0'
'_'
"192.168.000.025"
'_'
"255.255.255.0"
'_'
"192.168.000.010"
'_'
'0'
'_'
"192.168.000.032"
?
03
P7001R & P7002R Series Converters
Length
Description
(bytes)
1
STX
1
No of bytes in message
1
Address
1
Message instruction
1
Ethernet Message sub instruction
1
Checksum
1
ETX
Length
Description
(bytes)
1
STX
1
No of bytes in message
1
Address
1
Message instruction
1
Ethernet Message sub instruction
1
DHCP
(0 = Disabled)
(1 = Enabled)
1
Separator character
15
Ipv4 address
1
Separator character
15
Subnet mask
1
Separator character
15
Gateway address
1
Separator character
1
SNMP
(0 = Disabled)
(1 = Enabled)
1
Separator character
15
SNMP trap address
1
Checksum
1
ETX