Data
Supply voltage
Isolation class
Max. Leistungsverbrauch
Control voltage
Capacity
Water inlet pressure
Water inlet volume
Water inlet temperature
Temperature
Capacity:
The figures show the max
3
m
/h (l/min) the pumps
can deliver at an inlet
pressure of 2 bar and
following end pressures
30 bar:
35 bar:
40 bar
Approvals:
Weight:
Dimensions (H x B x T):
MP44
Siehe
Typenschilder auf
Motoren
IP54
60 kW
24 VAC
3
0-44m
/h
2-4 bar
3
Min. 44 m
/h
Max. 70°C
5-40°C
44,8 (753)
39,6 (660)
33,0 (550)
CE
1400 kg
2000 x 1500 x 1800
mm
MP66
Siehe
Typenschilder auf
Motoren
IP54
90 kW
24 VAC
3
0-66m
/h
2-4 bar
3
Min. 66 m
/h
Max. 70°C
5-40°C
67,2 (1130)
59,4 (990)
49,5 (825)
CE
1750 kg
2000 x 1500 x 2500
mm
MP88
Siehe
Typenschilder auf
Motoren
IP54
120 kW
24 VAC
3
0-88m
/h
2-4 bar
3
Min. 88 m
/h
Max 70°C
5-40°C
89,6 (1506)
79,2 (1320)
66,0 (1100)
CE
2800 kg
2000 x 1500 x 3200
mm