Product Manual Thrii-Tap+ D Hand Wash
Dryer
6. For further adjustments repeat steps 1 to 5, or to exit the programming
mode momentarily press the Menu Select button. A 20 second period of
inactivity will automatically exit the programming mode and revert to
displaying the time.
Instructions can be downloaded from the Wallgate web site or contact Wallgate Ltd
to:
✓ Restore the unit to factory default settings.
✓ Instructions to change the cycle sequence of soap – water – hand dryer.

8.2.1. Hygiene Purge Adjustment

Follow the instructions in the previous section to enter and navigate the F-Functions
menu. F54 and F55 sets the time of day to purge, F56-F62 enable/disable specific
days to purge, the repeat setting (F63) refers how many purges required, interval is
the time between purges (F64) and the run time (F65) is the water purge time.
Description
Automatic Hygiene Mode
0 ~ Hygiene Flush Off.
1 ~ Hygiene Flush On.
Auto Hygiene Flush Start
Hour
Auto Hyg. Flush Start Minute
Auto Hygiene Day 1
Auto Hygiene Day 2
Auto Hygiene Day 3
Auto Hygiene Day 4
Auto Hygiene Day 5
Auto Hygiene Day 6
Auto Hygiene Day 7
Auto Hygiene Repeat
Auto Hygiene Interval
Auto Hygiene Run Time
Figure 22: Purge Adjustment table.
Factory
Setting range
Settings
Min.
1
0
0
0
0
0
On
Off
Sun.
On
Off
Mon.
On
Off
Tue.
On
Off
Wed.
On
Off
Thu.
On
Off
Fri.
On
Off
Sat.
1
0
23
1
1
0
Revision 2
Function
Max
Increment
1
1
F53
23
1
F54
59
1
F55
On
F56
On
F57
On
F58
On
F59
On
F60
On
F61
On
F62
23
1
F63
23
1
F64
59
1
F65
32