When installed, the
thermostat may have*
the ability to:
Control a compatible
humidifier
Display relative humidity
level as measured at the
thermostat
Dehumidify (Cool to
dehumidify, reheat, control a
dehum. terminal equipped
furnace board.
Compatible with thermostat models:
33CS450-01, 33CS420-01 &
33CS400-01
for a complete list contact Carrier
Complete Control from
Carrier Corporation - 08/06 - Patents Pending
P/N 33CSHUMID-01
P/N
33CSHUMID-01
Humidity
Humidity
Module
Module

Advertisement

loading

Summary of Contents for Carrier P/N 33CSHUMID-01

  • Page 1 Dehumidify (Cool to dehumidify, reheat, control a dehum. terminal equipped furnace board. Compatible with thermostat models: 33CS450-01, 33CS420-01 & 33CS400-01 for a complete list contact Carrier Complete Control from Carrier Corporation - 08/06 - Patents Pending P/N 33CSHUMID-01 33CSHUMID-01 Module Module...
  • Page 2 Depending on the model number of your thermostat the humidification options are: View the ambient humidity at the thermostat location Control a humidifier with the HUM terminal on the thermostat Dehumidify using only the air conditioner Dehumidify with Reheat using your HVAC’s...
  • Page 3: Installation

    Installation The humidity accessory is inserted into the humidity plug on the back of the thermostat and the Humidity Jumper is set for HUM operation. ELEC PROG DEHUM (MISC1 MISC3 MISC2 MISC1 ONLY) MISC1 MISC2 MISC3 RS+5 CKGND INSTALL HUMIDITY MODULE WITH SENSING RSGND ELEMENT OUTWARD...
  • Page 4 Humidity Operation To control a MISC output for humidification, place the MISC1, MISC2, or MISC3 jumper on the term- inal labeled HUM. This will supply 24VAC to the selected MISC terminal on the backplate of the thermostat when the humidity in the home falls below the setpoint you have chosen.
  • Page 5 Dehumidifying With The DEHUM Terminal* Dehum Terminal: To control a MISC output for dehumidification, place the MISC1, MISC2, or MISC3 jumper on the terminal labeled DEHUM. This will supply 24VAC to the selected MISC terminal when the humidity in the home is above the setpoint you have chosen.
  • Page 6 Dehumidifying With Air Conditioning* Cool to Dehumidify: If Cool to Dehumidify is on and the Humidity Module is installed, the thermo- stat has the ability to initiate a cooling cycle for advanced dehumidification operation. When the thermostat detects the humidity percentage is above the setpoint for dehumidification, and heating or cooling is not on, the thermostat will force the compressor to run with the fan, thus reducing...
  • Page 7 Reheat with Cool to Dehumidify* Reheat: This feature allows the thermostat to turn on Electric Heating (W2) during Cool to Dehumidify (see previous page) to maintain room temperature until the dehumidification setpoint is reached. The cooling cycle will allow for the dehumidification of the air to occur while the Electric Heating will allow for a constant room temperature.
  • Page 8 The Up and Down buttons alter the flashing icon. The mode button advances the display to the next screen. Rev. 1 www.carrier.com Humidity - Press the humidity button to display the humidity screens. The Up and Down buttons alter the flashing icon.
  • Page 9: Warranty

    Warranty One-Year Warranty - This Product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer’s sole option to replace any defective part, will be provided without charge for the part itself provided the defective part is returned to the distributor through a qualified servicing dealer.