SAFETY CONSIDERATIONS
Installation of this accessory can be hazardous due to sys-
tem pressures, electrical components, and equipment location
(such as a roof, or elevated structure).
Only trained, qualified installers and service technicians
should install, start up, and service this equipment.
When installing this accessory, observe precautions in the
literature and on any labels attached to the equipment, and all
other safety precautions that may apply.
• Follow all safety codes.
• Wear safety glasses and work gloves.
• Use care in handling and installing this accessory.
ELECTRIC SHOCK HAZARD
To avoid the possibility of electrical shock,
open and tag all remote disconnects before
installing this equipment.
INTRODUCTION
The remote cooler mounting accessory permits indoor relo-
cation of the cooler from 30GTN, GTR, GUN, GUR units up
to 75 ft (22 m) away from the base unit. Relocating the cooler
introduces minimal line losses if correct piping practices are
followed. See Table 1 for the number of accessory packages re-
quired for each unit and for the package contents.
In addition to the parts supplied with the accessory package,
the following material must be field-supplied:
• refrigerant-grade liquid and suction line piping (length
determined by installation). See Table 2 for connection
sizes.
• pressure relief valves and fittings
UNIT 30GTN, GTR,
GUN, GUR
040
045
050
060-110,
230B-315B
130, 150,
230A-255A
170-210, 270A-315A
330A/B-420A/B
LEGEND
ODS — Outside Diameter, Sweat
* On unit sizes 040-110 and 230B-315B, the actual liquid line is
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
PC 903
Catalog No. 563-000
Book 2
Tab
5c

Installation Instructions

Part No. 30GT911050
Table 2 — Cooler Refrigerant-Line Connection Sizes
COOLER SUCTION LINE CONNECTIONS
60 Hz Units
Circuit A
Circuit B
5
5
1
/
1
/
8
8
5
5
1
/
1
/
8
8
2
1
1
/
2
/
8
8
1
1
2
/
2
/
8
8
2
5
/
2
5
/
8
8
3
1
/
3
1
/
8
8
7
/
inch.
8
Printed in U.S.A.
30GTN,GTR,GUN,GUR040-420
Remote Cooler Mounting Accessory
• suction flange gasket
• suction line tubing insulation (length determined by
installation)
5
/
-in. strain relief
8
• conduit (length determined by installation)
Table 1 — Unit Application
UNIT 30GTN,
GTR, GUN,
COOLER*
GUR
040
10HB040
045, 050
10HB050
060, 070
10HB070
080, 090,
230B, 245B
10HB090
100, 110,
255B, 270B,
10HB110
290B, 315B
130, 150,
230A, 245A
10HB160
255A
170,190,
270A, 290A,
330A/B, 360A/B,
10HB200
390B
210, 315A,
390A,
10HB210
420A/B
LEGEND
EXV — Electronic Expansion Valve
* For modular units (230-420), quantity listed is per module.
† For modular units (230-420), 1 package required for Module A
and 1 package required for Module B; total of 2 packages required
per unit.
(in. ODS)
50 Hz Units
Circuit A
5
1
/
8
5
1
/
8
5
1
/
8
1
2
/
8
2
5
/
8
3
1
/
8
Form 30G-22SI
50/60 Hz
ACCESSORY
(QTY)
PACKAGE
PACKAGES
CONTENTS
REQUIRED†
(1)
2 Shutoff Valves
1
(1)
200 ft (61 m)
1
5-Wire Jacketed
(1)
1
2 100-ft (30.5 m)
(1)
1
EXV Cable
Assemblies
(1)
1
1 Junction Box
(1)
1
1 Junction Box
(1)
1
8B-18 x
2 Screws,
(1)
1
/
1
COOLER
LIQUID LINE
CONNECTIONS
(in. ODS)
Circuit B
5
1
/
8
1
2
/
8
1
2
/
8
1
2
/
1
1
8
2
5
/
8
3
1
/
8
Pg 1
6-99
Replaces: 30G-17SI
Cable
Cover
1 Screw,
"
3
/
8
"
5
-14 x
/
4
8
/
*
8

Advertisement

loading

Summary of Contents for Carrier 30GTN

  • Page 1: Installation Instructions

    1 Junction Box 10HB160 255A Cover The remote cooler mounting accessory permits indoor relo- 170,190, cation of the cooler from 30GTN, GTR, GUN, GUR units up 1 Screw, 270A, 290A, ″ 8B-18 x 330A/B, 360A/B, to 75 ft (22 m) away from the base unit. Relocating the cooler...
  • Page 2: Installation

    Also ensure that there is sufficient room to remove parts. File a claim with the shipping agency if parts are cooler tubes if required for future service. damaged. Notify your Carrier representative if any item is missing. 2. Determine the new location for the cooler(s). Ensure...
  • Page 4 LEGEND EXV — Electronic Expansion Valve TXV — Thermostatic Expansion Valve Fig. 2 — Liquid Line Piping...
  • Page 5 Fig. 3 — 30GTN,GTR,GUN,GUR Control Box (Typical, Size 080-110 and Associated Modular Units Shown) The junction box supplied with the accessory is for 15. Select one jacketed cable and strip back the jacket on splicing the thermistor leads from the cooler with the both ends to expose the 5 wires.
  • Page 6 For installation instructions. 30GTN, GTR, GUN, GUR units connect the wires to 19. Perform all pre-start-up and start-up procedures speci- MBB-J8 (Main Base Board) for T1, T2, T5 and T6.
  • Page 7 PL-EXVB MAIN BASE BOARD EXV-B REMOTE SPACE TEMP (ACCESSORY) PL-EXVA OUTDOOR-AIR TEMP (ACCESSORY) EXV-A COOLER ENTERING FLUID TEMP COOLER LEAVING FLUID TEMP ELECTRONIC EXPANSION VALVES (EXVs) SATURATED Fig. 6 — EXV Connections to EXV Board — CONDENSING TEMP- CIRCUIT B EXV-J6 and EXV-J7 SATURATED SUCTION TEMP-...
  • Page 8 Copyright 1999 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. PC 903 Catalog No. 563-000 Printed in U.S.A. Form 30G-22SI Pg 8 6-99 Replaces: 30G-17SI Book 2...

This manual is also suitable for:

GtrGunGur040-420