Download Print this page
Carrier 338106-754-CBP Installation Instructions Manual

Carrier 338106-754-CBP Installation Instructions Manual

Blower housing service kit for 35-in. tall high efficiency condensing gas furnace

Advertisement

Quick Links

338106- -754- -CBP
338106- -755- -CBP
338106- -756- -CBP
338106- -757- -CBP
NOTE: Read the entire instruction manual before starting the
installation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory- -authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these
instructions
thoroughly and follow all warnings or cautions
include in literature and attached to the unit. Consult local building
codes, the current editions of the National Fuel Gas Code (NFGC)
NFPA 54/ANSI Z223.1 and the National Electrical Code (NEC)
NFPA 70.
In Canada, refer to the current editions of the National Standards of
Canada CAN/CSA- -B149.1 and .2 Natural Gas and Propane
Installation Codes, and Canadian Electrical Code CSA C22.1.
Recognize safety information. This is the safety- -alert symbol
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and
CAUTION. These words are used with the safety- -alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
Follow all safety codes. Wear safety glasses and work gloves. Have
a fire extinguisher available.
WARNING
!
FIRE, EXPLOSION, ELECTRICAL SHOCK
HAZARD
Failure to follow this warning could result in personal injury,
death and/or property damage.
The ability to properly perform maintenance on this equipment
requires certain knowledge, mechanical skills, tools, and
equipment. If you do not possess these, do not attempt to
perform any maintenance on this equipment other than those
procedures recommended in the Home Owner's Information
Manual.

Installation Instructions

Blower Housing Service Kit
For 35---in. Tall High Efficiency
Condensing Gas Furnace
WARNING
!
FIRE,
EXPLOSION,
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury,
death and/or property damage.
Improper
installation,
maintenance, or use can cause carbon monoxide poisoning,
explosion, fire, electrical shock, other conditions, which could
result in personal injury or death. Consult your distributor or
branch for information or assistance. The qualified installer or
agency must use only factory- -authorized kits or accessories
when servicing this product.
WARNING
!
ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury or
death, or property damage.
Before installing, modifying, or servicing system, main electrical
disconnect switch must be in the OFF position and install a
.
lockout tag. There may be more than one disconnect switch.
Lock out and tag switch with a suitable warning label. Verify
proper operation after servicing.
INTRODUCTION
This instruction covers the blower housing installation on 35 in.
tall condensing gas furnaces. The blower housing should be
replaced when there is visible damage to the blower housing.
DESCRIPTION AND USAGE
The blower housing replacement kit can be utilized to restore units
having blower assemblies that require repair. This kit contains the
following items: Blower housing assembly with cut- -off plate and a
loose parts bag with screws. See Table 1 for kit usage. See Table 2
for kit contents.
A replacement motor and blower wheel are NOT included in this
kit and must be ordered separately.
Table 1
INPUT
BTUH
40,000
60,000
80,000
100,000
120,000
ELECTRICAL
SHOCK
adjustment,
alteration,
Kit Usage
KIT NUMBER
WHEEL SIZE
338106--- 757--- CBP
338106--- 754--- CBP
338106--- 755--- CBP
11 x 10
338106--- 756--- CBP
11 x 11
AND
service,
11 x 7
11 x 8

Advertisement

loading

Summary of Contents for Carrier 338106-754-CBP

  • Page 1: Installation Instructions

    Blower Housing Service Kit 338106- -754- -CBP For 35---in. Tall High Efficiency 338106- -755- -CBP Condensing Gas Furnace 338106- -756- -CBP 338106- -757- -CBP Installation Instructions NOTE: Read the entire instruction manual before starting the WARNING installation. SAFETY CONSIDERATIONS FIRE, EXPLOSION, ELECTRICAL SHOCK...
  • Page 2: Installation

    WARNING Table 2 Kit Contents Quantity Description Blower Cut--- off CARBON MONOXIDE POISONING HAZARD Blower Housing Assembly Failure to follow this warning could result in personal injury or Hex Head Screw --- #10 x1/2” death. Hex Head Screw --- #8 x 3/8” Hex Head Screw --- #8 x 3/4”...
  • Page 3 Disassemble Blower Assembly Figure 2 Detail of External Pipe Support CAUTION UNIT OPERATION HAZARD Failure to follow this caution may result in unit damage or improper operation. Label all wires prior to disconnection when servicing controls. PRUDENCE D’EQUIPEMENT D’OPERATION Toute erreur de câblage peut être une source de danger et de panne.
  • Page 4: Fire Or Explosion Hazard

    Install the Blower Assembly Unit Checkout 1. Align the blower assembly with the rails in the blower deck WARNING and push backward to slide the blower into the blower com- partment. FIRE OR EXPLOSION HAZARD 2. If the furnace is installed in the downflow position, raise the blower up slightly to prevent the blower assembly from Failure to follow this warning could result in personal injury, catching on the blower deck.
  • Page 5 S Low temperature rise: Set unit for correct temperature rise range installation instructions. For additional information, and a as shown on unit rating plate. complete sequence of furnace operation, refer to furnace S Contaminated combustion air: Remove contaminates or provide Installation, Start- -Up and Operating Instructions.
  • Page 6 Catalog No: IIK--- 338106--- 02 Printed in U.S.A. Edition date: 09/11 Copyright 2011 CAC/BDP S 7310 W. Morris St. S Indianapolis, IN 46231 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: IIK--- 338106--- 01...