Approved Applications Compliance Guide; Listings And Approvals; Fire; Burglary - Radionics D9000 Series Operation And Installation Manual

Control/communicator
Table of Contents

Advertisement

Approved Applications Compliance Guide

Listings and Approvals

Fire

UL
Underwriters Laboratories lists the D9412, D9112,
D7412, and D7212 Control/Communicators as
Signal System Control Units for:
Central Station, Local, Auxiliary, Remote Station,
and Household Fire Warning.
CSFM
Approved by the California State Fire Marshal.
NYC-MEA
Approved by New York City's Materials and
Equipment Acceptance System.
Factory Mutual (FM)
Approved by Factory Mutual.

Burglary

UL
Underwriters Laboratories lists the D9412, D9112,
D7412, and D7212 Control/Communicators for:
Central Station, Local, Police Connect, Bank Safe
and Vault, Mercantile Safe and Vault, and Grade A
Household systems.
Department of Defense (DOD)
The D9412, D9112, D7412, and D7212 have
been granted approval for Department of Defense
(DOD) installations in Sensitive Compartmented
Information Facilities (SCIF).

Introduction

The System Chart references components
evaluated and listed by Underwriters' Laboratories
for compatibility with the Control/Communicator.
These components meet the basic system
requirements for the applicable standard.
The System Wiring Diagram, Issue A shows the
relationship between the panel and the accessory
components referred to in the System Chart.

Optional Compatible Equipment

You can use UL listed components that do not
require evaluation for electrical compatibility in many
applications when installed according to the
manufacturer's instructions.
74-07692-000-C 4/97
www.PDF-Zoo.com
D9000/D7000 Series Operation & Installation Manual
Page 54
firealarmresources.com

Burglary Applications

You can use UL listed burglary alarm sensors that
do not require evaluation for electrical compatibility
in burglary applications. In some cases you must
use a UL listed Radionics interface module in
conjunction with the sensors. Consult the individual
component specification and installation documents
to determine suitability.
Test weekly: UL Standard 1023 requires a
weekly test for residential burglary applications.

Bank Safe and Vault Applications

You must use the UL listed Model 5110 Bell and
Model 4001-42 External Line Balancer (both made
by Rothenbuhler) for the bell and balanced line
module in bank safe and vault applications.
Modifications must be made to the Radionics
D8108A enclosure to meet UL standard 681. See
the Radionics Technogram D7212/D9112 UL
Certificated Bank Safe and Vault Applications (73-
07302-000).
Test bell at arming: UL Standard 365 requires a
bell test at arming for bank safe and vault
applications.

Fire Applications

You can use UL listed fire initiating devices not
requiring electrical compatibility evaluation in any
application. For example: 4-wire smoke detectors,
heat detectors, water flow switches, and manual
pull stations are suitable fire initiating devices.
Consult the individual component specification
and installation documents to determine
suitability.
Two-wire smoke detectors only connect to the
panel through the D125B Powered Loop Interface
so that an earth ground will not cause an alarm.
Two-wire detectors must be evaluated for
electrical compatibility, and must be UL listed for
use with the panel. See the Radionics
Technogram Smoke Detectors Compatible with
the D9000/D7000 (33284), or you may contact
the detector manufacturer.
Other initiating devices, including four-wire smoke
detectors connect to the panel through the D129
Dual Class A Initiation Circuit Module, the D125B
Powered Loop Interface, or D8127 or D9127
POPITs. When using 4-wire smoke detectors,
install a suitable power supervision unit according
to the manufacturer's instructions. Use the D130
Relay Module, D8129 OctoRelay, or terminal 8,
Switched Aux Power to provide reset capability.
See the Off-Board Relays section of this manual
for details on the installation of the D8129.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7000 seriesD7212bD7212b1D9412D9112D7412 ... Show all

Table of Contents