3.Debug Mode

Additional displays as follows can be seen by turning Debug mode ON (C091 ->1).

3.1 Monitor mode

No
Functional
1
Control frequency monitor
2
Direct-current voltage monitor
3
BRD on-monitor
4
Electronic thermal monitor
5
Gate array trip factor monitor
6
MCU No. monitor
d101 ( Output frequency monitor (Hz)): Monitor of the output frequency of the inverter.
d102 ( DC bus voltage monitor (V)): Monitor of the DC bus voltage (VPN) of the inverter.
d103 ( BRD ON monitor (s)): There is an integrated BRD circuit on 11kW and less for SJ300, and 15kW and less
d104 ( Electronic thermal monitor (%)):You can find the usage ratio of electronic thermal performance as %.
d105 (Trip cause monitor of gate array):There are 8 items of trips which are detected by the internal gate array
Bit7
bit6
Gate array
IGBT error
error
W phase
(E23)
(E30)
Contents of d105 are expressed in HEX.
(Example 1)
20
20 (HEX) = 00100000 (BIN)
bit5 = "1" -> IGBT error (V phase)
(Example 1)
62
62 (HEX) = 01100010 (BIN)
bit1, bit5, bit6 = "1 " -> IGBT error (U, V, W phase)
d106(MCU No monitor): Display the software management number of MCU incorporated.
Display code
d101
d102
d103
d104
d105
d106
for L300P series. You can find accumulated turning ON time for the integrated BRD
transistor.
and these items are transmitted to MCU.
Bit5
bit4
Over
IGBT error
temperature
V phase
(E21)
(E30)
3- 1
SJ300/L300P A Monitor or data range
0.00-99.99/100.0-400.0Hz
0.0-999.9V
0.00-99.99/100.0s
0.00-99.99/100.0%
00-FF
0000-9999
bit3
bit2
Over voltage
Under voltage
(E07)
(E09)
bit1
bit0
Option
IGBT error
Ground fault
U phase
(E14)
(E30)