Function mode
Code
Function name
b034
RUN time/Power ON time level
b035
Operation direction restrict
b036
Start reduced voltage
b037
Display selection
b040
Torque limit mode selection
Torque limit level 1 setting
b041
(Forward-driving at
4 quadrant mode)
Torque limit level 2 setting
b042
(Reverse-regenerating at
4 quadrant mode)
Torque limit level 3 setting
b043
(Reverse-driving at
4 quadrant mode)
Torque limit level 4 setting
b044
(Forward-regenerating at
4 quadrant mode)
b045
Torque LAD-STOP selection
Reverse run prevention
b046
selection
Selection of non-stop
b050
function at instantaneous
power failure
Start voltage of non-stop
b051
function setting
OV LAD-STOP level of non-
b052
stop function setting
Deceleration time of non-
b053
stop function setting
Deceleration frequency widt h
b054
of non-stop function setting
b080
AM adjustment
b081
FM adjustment
b082
Start frequency adjustment
b083
Carrier frequency setting
b084
Initialize mode
b085
Country code for initialization
Frequency scalar conversion
b086
factor
b087
STOP key enable
Resume on FRS cancellation
b088
mode
b090
BRD usage ratio
b091
Stop mode selection
b092
Cooling fan control
b095
BRD selection
b096
BRD ON level
b098
Thermistor selection
b099
Thermistor error level
b120
Braking control selection
Waiting time for
releasing
b121
braking conformation
b122
Waiting time for acceleration
b123
Waiting time for stop
Waiting
time
for
b124
conformation
b125
Releasing frequency
b126
Releasing current
C091
Debug mode selection
C101
UP/DWN selection
C102
Reset selection
Reset f frequency matching
C103
selection
Overload
advance
C111
level
C121
O zero adjustment
C122
OI zero adjustment
C123
O2 zero adjustment
(Note) < > indicate the setting range of 75 to 150kW
0.-9999./1000-6553(10000-65530)hr
00(Reverse is valid)/01(Only forward)/02(Only reverse)
00(Start reduced voltage time small)-06(Start reduced voltage time large)
00(all display)/01(each function display)/02(User setting / main setting)
00(4 quadrant mode)/01(Terminal operation)/
02(Analog input)/03(Option1)/04(Option2)
0.-200.(%)/no(Invalid) <0.-180.(%)/no(Invalid)>
0.-200.(%)/no(Invalid) <0.-180.(%)/no(Invalid)>
0.-200.(%)/no(Invalid) <0.-180.(%)/no(Invalid)>
0.-200.(%)/no(Invalid) <0.-180.(%)/no(Invalid)>
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.5-15.0(kHz) Derating enable, <0-10kHz>
00(Trip history clear)/01(Data initialization)/
02(Trip history clear + data initialization)
00(Interior)/01(EC)/02(USA)
00(0Hz start)/01(Start f-equaling)
00(deceleration stop)/01(Free-run stop)
01(ON during run, After power ON, then for 5 minutes on stop is implied.)
00(invalid)/01(valid<invalid during stop>)/02(valid<valid during stop>)
00(invalid)/01(Positive temperature coefficient enable)/02 (NTC enable)
signal
0.00-99.99/100.0-400.0(Hz)
0.00*rated current-2.00*rated current(A)
00(No display)/01(Display)
00(No frequency data)/01(Keep frequency data)
00(Trip cancel during ON)/01(Trip cancel during OFF)/
02(Valid only during trip<Cancel during ON>)
00(0Hz start)/01(Start f-equaling)
notice
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
SJ300 Setting range
00(Invalid)/01(Valid)
00(Invalid)/01(Valid)
00(Invalid)/01(Valid)
0.0-1000.(V)
0.0-1000.(V)
0.00-10.00(Hz)
0. - 255.
0. - 255.
0.10-9.99(Hz)
0.1-99.9
00(valid)/01(invalid)
0.0-100.0(%)
00(Always ON)/
330-380/660-760(V)
0. - 9999. ( ohm)
00(Invalid)/01(valid)
0.00-5.00(s)
0.00-5.00(s)
0.00-5.00(s)
0.00-5.00(s)
0.0-2.0*rated current(A)
1- 7
Initial data
Note
-FE/-FU/-F
0.
00
06
00
00
150.
150.
150.
150.
00
00
00
0.0
0.0
1.00
0.00
180
60
0.50
5.0 <3.0>
00
01/02/00
1.0
00
00
0.0
00
00
00
360/720
00
3000.
00
0.00
0.00
0.00
0.00
0.00
Rated
current of
inverter
00
00
00
00
Inverter
rated
current
Set on
forwarding
Set on
forwarding
Set on
forwarding

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj300 series

Table of Contents