Adjusting The Fan Speed - Hisense KFR 2101GWE Instruction Manual

Split type air conditioner
Table of Contents

Advertisement

Adjusting the Fan Speed

A. Automatic
Simply set the FAN SPEED selector to the
A microcomputer in the air conditioner automatically controls the fan speed when the
co nditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is detected by
the microcomputer which then automatically switches the fan speed to the most suitable level.
Cooling mode:
When difference between room temperatureand set
temperature is
RT ≥ T+3℃
T+3℃ > RT ≥ T+1℃
RT< T+1℃
Mild drying mode:
When difference between room temperature
and set temperature is
RT ≥ T+5℃
T+5℃> RT ≥ T+3℃
Rt≤T+3℃
Heating mode:
When difference between room temperature
and set temperature is
RT < T-3℃
T-3℃< RT ≤ T-1℃
T-1℃< Rt<T
NOTE
The above table assumes that the sensor on the remote control is being used. If the sensor in the indoor unit is
being used (the
B. Manual
position.
AUTO
                      
                      
                      
indicator is on), actual operation may differ slightly from the operation described in table.
If you want to adjust fan speed manually during operation, just set the FAN SPEED selector
as desired.[
(High),
FAN SPEED
FAN SPEED
FAN SPEED
(Medium), or
(Low)]
10
mode is selected. When the air
AUTO
High
Medium
Low
High
Medium
Low
High
Medium
Low