7.3

Opening the burner

Disconnect the electrical supply from the burner
by means of the system main switch.
DANGER
Close the fuel shut-off valve.
DANGER
Wait for the components in contact with heat
sources to cool down completely.
 To separate the burner from the combustion head, proceed
as follows (Fig. 43):
 Remove the cover from the shelf 1), the pin 2), the retainers
4) and the screws 3).
 Disconnect the pipes 6).
 Disconnect the tie-rod of the gas butterfly valve removing the
screw 11).
 Pull out the burner from the combustion head by approx.
100÷120 mm and release the driving fork 7) by removing the
screws 10).
 At this point, it is possible to fully pull out the burner from the
pins 5).
 Fix the blast tube to the boiler by inserting the insulating
flange gasket 9) in-between.
 Fit the burner on the pins 5) leaving it open by approx. 100 ÷
120 mm.
 Refit the fork 7) fixing it with the screws 10).
 Completely close the burner fastening it with screws 3), fit
the retainers 4), the split pin 2), the gas butterfly valve tie-rod
11) and the pipes 6).
 With burner open, it is possible to separate the gas sleeve 8)
from the blast tube.
7.4

Closing the burner

Refit following the steps described but in reverse order; refit all
burner components as they were originally assembled.
After carrying out maintenance, cleaning or
checking operations, reassemble the cover and
all the safety and protection devices of the burner.