2.11.1
Definition of an I/O Expansion Bus
The I/O expansion bus of the 7188X/7521 series can be divided into 3
groups as follows:
1. Power supply & reset signals: VCC, GND, RESET, /RESET
2. , Parallel Bus:
System clock: CLOCKA
Asynchronous ready control: ARDY
Address bus: A0 ~ A6, A7 (7188XC & 7521 series without A7)
Data bus: D0 ~ D7
Interrupt control: INT0, INT1, INT4 (7188XC & 7521 series
without INT4)
Chip select & read/write strobe: /CS, /WR, /RD
3. Serial Bus: TO_0, TO_1, TI_0, TI_1, SCLK, DIO9, DIO4, DIO14
Refer to "I/O Expansion Bus for 7188X/7188E User' s Manual" for more information.