Page 1
CONTINOUS MIXER SPIN 15 1106340 (115V 60Hz) IMER U.S.A. Inc. Part. number 3237384 R00 - 2019/07 221 Westhampton Place Capitol Heights, MD 20743 Machine serial N° Ph / 800.275.5463...
Page 2
At IMER U.S.A. we continually search for ways to better serve our customers. Should you have an idea or thought to share with us regarding this Product we would appreciate hearing from you. Our motto is "Tools and Services for the 21st Century".
Page 3
IMER INTERNATIONAL S.p.A. SPIN 15 FIG.1 ENGLISH SEZIONE A-A 1) WHEELED FRAME (2) HOPPER (3) MIXING CHAMBER (4) MATERIAL OFFLOAD PORT (5) ELECTRICAL PANEL (6) AUGER TYPE BATCHING SYSTEM (7) GEARMOTOR (8) MIXER (9) WATER CIRCUIT (10) HOPPER GRID (11)WATER PUMP...
Page 4
IMER INTERNATIONAL S.p.A. SPIN 15 SPIN 15A TECHNICAL DATA Machine code 1106340 - 115V 60Hz MAIN POWER SUPPLY WATER CONNECTION 1/2" GEARMOTOR WATER PUMP 0.45 MAXIMUM PRESSURE MAXIMUM POWER 7.75 MATERIAL FLOW RATE l/min (APPROX.) DIMENSIONS 1380 1165-1095-950 LOADING HEIGHT...
Page 5
(power L ) measured according to EN ISO 3744 (2000/14/CE) The hazardous points on the IMER mixer are protected by means of suitable safety devices, which must remain fitted at all times and 3. DESCRIPTION OF MIXER OPERATION kept in perfect condition.
Page 6
IMER INTERNATIONAL S.p.A. SPIN 15 8. INSTALLATION Position the mixer on a flat surface in a suitably ventilated envi- ronment where it does not constitute an obstruction either during use or cleaning at the end of the work shift. - Position the mixer on a flat surface or slightly inclined towards the material outlet.
Page 7
Check weekly that the plug and socket contacts are clean, dry and rust free. Every six months arrange for an inspection of the machine by an authorised IMER service centre. - Spent oil is a special waste. Therefore it must be disposed of according to current legislation.
Page 8
- Pump inlet water filter clogged - Pressure reducer water filter clogged - Pressure reducer faulty The water continues to exit Solenoid valve faulty - Contact an authorised IMER service centre from the mixing chamber when machine is stationary Material does not exit the...
IMER INTERNATIONAL S.p.A. SPIN 15 WIRING DIAGRAM - T1 - TRANSFORMER 25 VA 0-115-230/0-24V 50/60HZ F1 - PRIMARY FUSE 6.3X32 2A F2 - SECONDARY FUSE 6.3X32 2A EM - EMERGENCY STOP RT1 -AUTOMATIC SWITCH E1 - WATER ELECTROVALVE 24vca 50/60 hz...
Page 10
IMER INTERNATIONAL S.p.A. SPIN 15 WIRING DIAGRAM WATER PUMP 1107638 F1 - FUSE 6.3 X32 2 A KM - CONTACTOR 12A RT2 - SWITCH 10 A M2 - WATER PUMP MOTOR...
Page 13
IMER INTERNATIONAL S.p.A. SPIN 15 TAV.1 STRUTTURA MACCHINA - STRUCTURE DE LA MACHINE - MACHINE STRUCTURE - MASCHINESTRUKTUR - ESTRUCTURA DE LA MAQUINA Rif. Cod. NOTE 3226550 TELAIO CHÂSSIS FRAME RAHMEN BASTIDOR CONSOLIDACION RINFORZO PER RENFORCEMENT ENHANCEMENT FOR BESCHLAG GETRIEBE-...
Page 22
IMER INTERNATIONAL S.p.A. SPIN 15 REGISTRO DI MACCHINA, COLLAUDI, MANUTENZIONE - REGISTRE MACHINE, ESSAIS ET ENTRETIEN - MACHINE REGISTER ,TESTS AND MAINTENANCE - MASCHINENREGISTER, ABNAHMEN UND WARTUNG - REGISTRO DE MÁQUINA,PRUEBAS,MANTENIMIENTO RISULTATI, ANNOTAZIONI E FIRMA DEL COMPILATORE VERIFICA PARTI DELLA MACCHINA RÉSULTATS, ANNOTATIONS ET SIGNA-...
Page 23
IMER INTERNATIONAL S.p.A. SPIN 15 REGISTRO DI MACCHINA, COLLAUDI, MANUTENZIONE - REGISTRE MACHINE, ESSAIS ET ENTRETIEN - MACHINE REGISTER ,TESTS AND MAINTENANCE - MASCHINENREGISTER, ABNAHMEN UND WARTUNG - REGISTRO DE MÁQUINA,PRUEBAS,MANTENIMIENTO RISULTATI, ANNOTAZIONI E FIRMA DEL COMPILATORE VERIFICA PARTI DELLA MACCHINA RÉSULTATS, ANNOTATIONS ET SIGNA-...
20743 Ph / 800.275.5463 We warrant to the original purchaser that the IMER equipment described herein (the "equipment") shall be free from defects in material and workmanship under normal use and service for which it was intended for period of one (1) year from the date of purchase by the original purchaser.