5.9
Access to head internal part
In order to reach inside the combustion head (Fig. 16) proceed as
follows:
disconnect the gas servomotor socket 1);
disconnect the electrical connection from the gas pressure
switch 2);
remove the 4 fixing screws 3);
open the burner partially (approx. 150 mm) on the hinges;
5.10
Electrode positioning
Position the electrode on the ignition pilot observ-
ing the indications in Fig. 17.
WARNING
20089633
Installation
20094552
disconnect the cable of the pilot electrode 4);
open the burner fully;
extracting the inner part of the head 6), after unscrewing the
screws 5) that block it to the pipe coupling.