Access To Head Internal Part; Electrode Positioning - Riello RS 1300/EV C01 Modulating Operation

Forced draught gas burners
Table of Contents

Advertisement

5.9

Access to head internal part

In order to reach inside the combustion head (Fig. 16) proceed as
follows:
 disconnect the gas servomotor socket 1);
 disconnect the electrical connection from the gas pressure
switch 2);
 remove the 4 fixing screws 3);
 open the burner partially (approx. 150 mm) on the hinges;
5.10

Electrode positioning

Position the electrode on the ignition pilot observ-
ing the indications in Fig. 17.
WARNING
20089633
Installation
20094552
 disconnect the cable of the pilot electrode 4);
 open the burner fully;
 extracting the inner part of the head 6), after unscrewing the
screws 5) that block it to the pipe coupling.
Elettrodo
Electrode
20
GB
Fig. 16
Diffusore
Diffuser
20094554
Fig. 17