Page 3
Megahertz NOAA National Oceanic and Atmospheric Administration (USA) Rescue Coordination Centre SARSAT Search and Rescue Satellite Aided Tracking System Shore Based Maintenance Unique Identifier Number USCG Unite States Coast Guard jotron.com Doc. No.: 82819 Rev. K Page 3 of 48...
9.1.2 Stored in the FB-6 float free bracket ....24 9.1.3 Stored in the FB-42 float free brackets ....27 9.1.4 Stored in the FBH-42 float free brackets ..... 27 jotron.com Doc. No.: 82819 Rev. K Page 4 of 48...
Page 5
17 Recycling and disposal ............... 42 18 Warranty ..................42 19 Service ..................42 19.1 Service agents ..............43 20 Document revision log ............... 44 21 Emergency instructions ............. 46 jotron.com Doc. No.: 82819 Rev. K Page 5 of 48...
General Jotron manufactures safety products designed for the search and rescue of human lives and property. For this product to be effective according to the design parameters, it is imperative that it is handled, maintained, serviced and stowed in accordance with this manual.
Standards Jotron declares that this this product is compliant with IMO and SOLAS regulations and both MED and ROHS directives. A copy of the declaration of conformity can be downloaded from jotron.com. The Tron 40S MkII has been verified, tested and meets the following product standards: IEC 61097-2 Ed.
Page 10
SOLAS Chapter IV reg. 15.9.2 Regarding battery change. This must be and IMO MSC. Circ. 1039 completed at a Jotron SBM authorized location and it must also be approved by the VDR manufacturer. The interval is dependent on the flag-state administration.
Page 11
IMO MSC.1/Circ.1222 Regarding an additional yearly testing requirement for the Tron 40VDR float free capsule. IMO COMSAR/Circ. 32 (latest Correct installation and storage of this revision) product. jotron.com Doc. No.: 82819 Rev. K Page 11 of 48...
EPIRB from inadvertently being activated by moisture or water spray when placed in the bracket. The Tron 40S MkII includes of the following components: • Cospas-Sarsat emergency EPIRB jotron.com Doc. No.: 82819 Rev. K Page 12 of 48...
406.037 MHz frequency. After the Tron 40S MkII is activated, the next passing satellite will detect the transmitted signal and relay it to an antenna at a local user terminal (LUT) ground station. jotron.com Doc. No.: 82819 Rev. K Page 14 of 48...
IBRD: www.406registration.com If the country operates a national beacon registry, obtain a point of contact www.cospas-sarsat.org (review C/S S.007 Cospas-Sarsat Handbook of Beacon Regulations). Suggested EPIRB registration links: jotron.com Doc. No.: 82819 Rev. K Page 15 of 48...
To report a false alarm in the United States, contact the US Coast Guard at 1-855-406-USCG (8724) To report a false alarm outside of the US, contact the national authority where the beacon is registered. jotron.com Doc. No.: 82819 Rev. K Page 16 of 48...
Functional description Tron 40S MkII components An overview of the components. Figure 3 Illustration - Tron 40S MkII with float free bracket components jotron.com Doc. No.: 82819 Rev. K Page 17 of 48...
Item no. Item Front cover Tron 40S MkII EPIRB Bracket Hydrostatic release unit (HRU) Stability clip Catapult Cotter pin Table 1 Tron 40S MkII components Main module The main board includes all electronic circuity and the main switch. Antenna The antenna in the Tron 40S MkII is omnidirectional and includes a LED flash at the top.
The EPIRB should be mounted so that it can be easily released by a person and brought to a survival craft. Do not mount on a radar mast or on any other surface that can only be reached by vertical ladder. jotron.com Doc. No.: 82819 Rev. K Page 19 of 48...
Figure 4 Illustration - FB-6 float free bracket dimensions 7.1.2 Mounting the FB-42 float free bracket Refer to the user manual FB-42 heating bracket for steps regarding how to mount of this bracket. jotron.com Doc. No.: 82819 Rev. K Page 20 of 48...
Replacing the battery The Tron 60S MkII battery must be changed at a Jotron shore based maintenance (SBM) authorized workshop to be GMDSS compliant. If your Tron 60S MkII is not under any international or national regulations, the battery can be changed by authorized Jotron representatives/partners/dealers.
To manually operate the Tron 40S MkII out of the bracket, do the following: 1. Pull the safety ring. 2. Push and move the main switch to the ON position. jotron.com Doc. No.: 82819 Rev. K Page 22 of 48...
Page 23
The LED indicator located at the top of the antenna will start to flash. This indicates that the EPIRB is transmitting. 3. Tie the EPIRB lanyard to yourself or the survival craft. jotron.com Doc. No.: 82819 Rev. K Page 23 of 48...
The EPIRB can drop out of the FB-6 bracket when releasing the top cover. 4. Remove the cotter pin from the bracket. 5. Remove the cover. jotron.com Doc. No.: 82819 Rev. K Page 24 of 48...
Page 25
6. Remove the EPIRB from the bracket. 7. Pull the safety ring. jotron.com Doc. No.: 82819 Rev. K Page 25 of 48...
Page 26
The LED indicator located at the top of the antenna will start to flash. This indicates that the EPIRB is transmitting. 9. Tie the EPIRB lanyard to yourself or the survival craft. jotron.com Doc. No.: 82819 Rev. K Page 26 of 48...
Refer to the user manual FB-42 heating bracket for steps regarding how to operate a Tron 40S MkII stored in a FB-42 or FBH-42 float free bracket. The user manual is available for download at jotron.com - product. https://jotron.com/product/tron-40s-epirb-package/. 9.1.4 Stored in the FBH-42 float free brackets Refer to the user manual FBH-42 heating bracket for steps regarding how to operate a Tron 40S MkII stored in a FB-42 or FBH-42 float free bracket.
3. Transmission is indicated by the flashing LED light and will continue until the EPIRB is lifted out of the water and dried off. The transmission can also be stopped by placing the EPIRB back into the FB-6 bracket. jotron.com Doc. No.: 82819 Rev. K Page 28 of 48...
- product. https://jotron.com/product/tron-40s-mkii-fbh-42-heating-bracket/. Wrist strap In an emergency the EPIRB can be carried using a Jotron wrist strap. Use the strap when it is necessary to have both arms free. To use the wrist strap, do the following: jotron.com Doc.
Page 30
1. Pull the wrist strap out of the pocket. 2. Place your arm through the loop of the strap. It is not possible to put the wrist strap back into the pocket after use. jotron.com Doc. No.: 82819 Rev. K Page 30 of 48...
MSC. 1039 SBM. The SMB is decided by the flag state administration. Every 10 Jotron recommends that the Tron 40S MkII and any of the float years free brackets used are replaced at this time. Table 2 Tron 40S MkII maintenance requirements 10.1 Inspection...
When testing the 406MHz transmitter a test message is transmitted, this test message is coded with a special synchronization code that will not be recognized as an actual alert by the Cospas-Sarsat satellites. jotron.com Doc. No.: 82819 Rev. K Page 32 of 48...
Page 33
Keep hands and/or other objects away from the antenna. 3. Release the switch. A single flash indicates a passed test. If this is not the result, refer to the error codes. Figure 6 Illustration - self-test jotron.com Doc. No.: 82819 Rev. K Page 33 of 48...
A replacement HRU must be purchases separately and is supplied in a kit. The HRU kit includes a special bolt and fittings. Only a Jotron approved hydrostatic release unit kit must be used, as it is type approved. To replace the release mechanism, do the following: 1.
Page 35
2. Remove the cover. 3. Remove the EPIRB from the bracket. jotron.com Doc. No.: 82819 Rev. K Page 35 of 48...
Page 36
HRU by sliding it out of the locking slot. 5. While holding the catapult down, slide the new HRU into the locking slot. 6. Place the EPIRB back in the bracket. jotron.com Doc. No.: 82819 Rev. K Page 36 of 48...
Page 37
7. Verify no gaping between the bracket and cover. 8. Close and secure the top cover using the cotter pin. jotron.com Doc. No.: 82819 Rev. K Page 37 of 48...
Test and maintenance records Below is an overview of all test and control details. Date B/H/T* Signature Inspector name *B=New battery, H=New HRU, T=Test jotron.com Doc. No.: 82819 Rev. K Page 38 of 48...
The safety information is available for download at jotron.com - product. http://jotron.com/product/tron-40s-epirb-package/. 13.1 Handling and storage This product should be stored in a cool and well-ventilated area. Elevated temperatures can result in a reduction of battery life.
Bi Phase L Stability: Short term: ≤ 2x10e Medium term: ≤ 1x10e Residual noise: ≤ 3x10e Bit rate: 400bps Antenna: built-in omnidirectional 14.3 Homing transmitter Frequency: 121.500MHz Output power: Up to 100mW jotron.com Doc. No.: 82819 Rev. K Page 40 of 48...
Dimensions (H/W/D): 498mm x 227mm x 209mm Weight: 2000grams Release mechanism: Jotron HRU Temperature operating: -30°C to + 65°C (-22°F to +149°F) Temperature storage: -30°C to + 65°C (-22°F to +149°F) 14.4.2 FB-42 float free bracket Refer to the user manual FB-42 heating bracket for technical specification information regarding this bracket.
Refer to the sales terms and conditions for specific warranty information regarding this product. Service All services such as testing, installation, programming, replacement, marking and battery exchange are provided by an authorized Jotron service agent. Improper service or maintenance may destroy the functionality and/or performance of this product.
Jotron does not accept any responsibility for the dismantling or reassembling of any Jotron product that occurs externally from a Jotron authorized facility and/or is handled by someone other than an authorized, training and certified person. 19.1 Service agents Refer to jotron.com...
Corrected text (Total 42 oages) 12.07.2011 Added text (Total 36 pages) 16.12.2021 Updated content, revised text structure in a new documentation design and layout in accordance with new company profile. jotron.com Doc. No.: 82819 Rev. K Page 44 of 48...
Emergency instructions This is an overview of how to operate a Tron 40S MkII during an emergency. Figure 7 Emergency instructions overview jotron.com Doc. No.: 82819 Rev. K Page 46 of 48...
Page 48
NORWAY / HEADQUARTERS CHINA Jotron AS Jotron USA, Inc Norway Jotron AS Beijing Ringdalskogen 8 6300 Rothway Street, Suite C Representative Office (ATC business) 3270 Larvik, Norway Houston, TX 77040, USA No. 1204 room, building D Tel: +47 33 13 97 00...
Need help?
Do you have a question about the Tron 40S MkII EPIRB and is the answer not in the manual?
Questions and answers