Water Requirements - Triton T80sr PUMPED Manual

Electric shower
Table of Contents

Advertisement

*Diagrammatic view – not to scale.
For illustration purposes only.
Minimum capacity
114 litres (25 gallons)
Cold water
cistern
Stop
Gate
valve
valve
8 cm minimum
Shower
unit
Mains
water
supply
Separate permanently
connected supply
from consumer unit
T80sr pumped
*Fig.5
Mains electric supply
(via double pole switch)

WATER REQUIREMENTS

Water requirements
WARNING!
Under no circumstances must this
T80sr pumped shower be connected
directly to the mains water supply.
The installation must be in accordance with
Water Regulations/Bylaws.
To guarantee activating the heating elements,
the shower must be connected to a cold water
supply which is gravity fed from a static cold
water storage cistern with a minimum capacity of
114 litres (25 gallons).
There MUST be a maximum head of water of
10 metres and a minimum head of 8cm, as
measured between the bottom of the cistern and
the top of the shower unit.
There MUST be no other cold water draw-offs
between the cistern and the unit and the pipe
MUST NOT supply water to any other tap or
fitting at a lower level.
NOTE: The supply pipe from the cistern should
be on the opposite side to the float operated
valve to prevent air being drawn into the pipe
when the cistern is filling.
If it is intended to operate the shower in
hard water areas (above 200 ppm temporary
hardness) a scale inhibitor should be fitted.
Fig.5 shows a typical system layout.
DO NOT use jointing compounds on any pipe
fittings for the installation.
9