Data 2 Output Setting; Data 3 Output Setting; Selection Of Nmea0183 Or Log Pulse; Rate Of Log Pulse Output - Furuno GP-90 Installation Manual

Furuno gps receiver user manual
Hide thumbs Also See for GP-90:
Table of Contents

Advertisement

5. INITIAL SETTINGS

DATA 2 output setting

1) Press [MENU], [9] and [4]. The DATA 2 OUTPUT SETUP menu appears.
2) Follow the procedure for setting DATA 1 output.

DATA 3 output setting

The DATA 3 can output NMEA 0183 (V1.5/V2.0) /IEC 61162-1 data or log pulse by
selecting inner jumper wires. For NMEA 0183 (V1.5/V2.0) /IEC 61162-1, the same signal of
DATA 1 is output from DATA 3.

Selection of NMEA0183 or log pulse

Output data
NAV board
JP4 (2 pcs.)
JP5 (3 pcs.)

Rate of log pulse output

500 mA Max.
50 VDC
Procedure for setting of log pulse rate
1) Press [MENU], [9] and [3].
2) Press
or
to select DATA 3. Log Pulse.
3) Press
or
to select log pulse for external equipment; 200 ppm or 400 ppm.
4) Press the [ENT] key.
5) Press the [ESC] key.
14
DATA2 OUTPUT SETUP
Data Fmt.
Talker ID
Output Data
(00-90 sec)
1. AAM:00 APA:00
2. BWR:00 BWW:00 GGA:00 GLL:01
3. RMB:01 RMC:00 VTG:01 WCV:00
4. VDR:00 WPL:00 XTE:00 ZDA:01
5. GNS:00 GBS:01 Rnn:00 RTE:00
: Select
ENT : Enter
Setting shown here are default settings.
Figure 5-4 DATA 2 OUTPUT SETUP menu
NMEA 0183 (V1.5/
V2.0)/IEC 61162-1
(default setting)
ON
OFF
V1.5
V2.0
IEC
GP
LC
DE
100%
APB:04 BOD:00
MENU : Escape
Log pulse
OFF
ON