General Data; Rate Of Operation - Furuno GP-90 Installation Manual

Furuno gps receiver user manual
Hide thumbs Also See for GP-90:
Table of Contents

Advertisement

5. INITIAL SETTINGS
AGFPA: Autopilot information from FURUNO autopilot equipments
Port
Input
DATA1
NMEA 0183
DATA2
Ver. 1.5 /2.0
AGFPA , DBT, DPT,
HDG, HDM, HDT,
MTW, TLL, VBW,
VHW
DATA3
External MOB
DATA4
DGPS or general data
(Selected by menu)

General data

1) Input of waypoint data
Connect YEOMAN equipment to DATA4 port.
2) Input and output of waypoint / route data

Rate of operation

The TX rate of operation is the percentage of data output in one second, and it appears on
the screen. If short intervals are assigned to many sentences, the rate of operation
increases as illustrated below
Note: Output data should be less than 100%.
When the external equipment cannot display correct data input from the GP-90, the rate of
operation should be lowered. For example, set a rate of operation less than 60 % for the
Temperature Indicator TI-20.
12
IEC 61162-1/NMEA 0183 Ver.1.5/
Ver.2.0
AAM, APA, APB, BOD, BWC, BWR,
BWW, GGA, GLL, GNS, RMB, RMC,
VDR, VTG, WCV, WPL, XTE, ZDA,
GBS, Rnn, RTE
Same as the data output form "DATA1"
IEC 61162-1/NMEA 0183 Ver.1.5/
Ver.2.0
AAM, APA, APB, BOD, BWC, BWR,
BWW, GGA, GLL, GNS, RMB, RMC,
VDR, VTG, WCV, WPL, XTE, ZDA,
GBS, Rnn, RTE
TX
Output
LOG PULSE
General data
TX
TX