Page 2
Exploded diagram of the product Motor Earth bolt Motor arm Earth washer Gate leaf arm 12x27 clamp washer Gate leaf bracket Shaft bolt / motor arm HM 10x40 Electronic unit End stop cover bolt Motor cover 22a Upper stop cover Motor cover bolt 22b Lower stop cover Information card...
CONTENTS GENErAl INfOrmATION _______________________________________________________________ 2 SAfETy ______________________________________________________________________________ 2 Caution Safety instructions relating to installation PrOduCT dESCrIPTION _______________________________________________________________ 3 Size of motor (in mm) Technical data Description of operation of the indicators PrE-INSTAllATION ChECkS ___________________________________________________________ 4 Gate Pillars Reinforcements Area of application PrEPArATION ANd drIllING Of PIllArS ______________________________________________ 5 mOuNTING ANd fIxING Of ThE mOTOrS ________________________________________________ 6 INSTAllING ThE INTEGrATEd OPENING ENd STOP ______________________________________ 8...
This guide describes how to install, commission and operate this product. Follow all the instructions as incorrect installation can lead to serious injury. Any use outside the sphere of application specified by Somfy is forbidden. This invalidates the warranty and discharges Somfy of all liability, as does any failure to comply with the instructions given herein.
The selected safety accessories for the installation must comply with the current standards and regulations in force in the country in which the product is being installed. The use of any safety components not approved by Somfy remains the sole responsibility of the installer.
description of operation of the indicators rAdIO indicator light Radio frame received Off: No radio reception Lit: Radio command received Pedestrian opening indicator light Lights up when pedestrian opening is activated/ deactivated using one of the remote control buttons Automatic closing indicator light Off: Automatic closing mode not activated...
PrEPArATION ANd drIllING Of PIllArS For the indicated values, the gate leaves and their hinge pins are taken to be on the same axis. If the hinge pins are offset, the maximum opening angle values will be reduced. [1]. Measure dimension A. [2].
mOuNTING ANd fIxING Of ThE mOTOrS [1]. Open the upper cover using the specific key supplied. [2]. Unscrew the 2 bolts of the lower cover and remove. Info card: for improved legibility, use a permanent marker. [3]. Attach the motor, checking the level. [4].
Page 9
[5]. Unlock the motor arms using the button located on the top of the motor. : arms locked : arms unlocked - manual operation In unlocked position, move the arms slowly to avoid damaging the motors. [6]. To ensure correct closing of the gate, push the motor arm and the gate firmly: - the gate arm must be completely unfolded, - the mounting tab must be flat against the reinforcement,...
INSTAllING ThE INTEGrATEd OPENING ENd STOP [1]. Manually open the gate to the opened position α required. α [2]. Install the end stop on the bracket side, flush against the shoulder of the motor arm. Do not tighten the stop. [3].
ElECTrICAl CONNECTIONS Cable guide fitting Fit the cable guides on the two motors. Connecting the motors Motor M1 actuates the gate leaf that opens first and closes last, and opens for pedestrian access. [1]. With the gate closed, identify the location of motor M1 by identifying the gate leaf that will open first.
locking the arms [1]. Close the two gate leaves and lock the arms by pressing them. [2]. Turn the motor locking handles to the locked position . Switching the installation on Switch the installation on. indicator light on the electronic unit will flash (2 pulses) to indicate that the motors are on and awaiting setting. If the indicator light stays off, refer to the repair help on page 17.
Gate travel self-learning Self-learning of the gate's travel is essential when commissioning the motor. The gate must be closed before auto programming is started and at least one remote control must have been programmed. Auto-programming consists of making the gate perform two gate leaf opening and closing cycles.
When using your gate in automatic mode, standard EN 12 453 requires a set of photoelectric cells to be installed (see wiring on page 13). It is only possible to switch to the automatic operating mode if a set of photoelectric cells is installed. Somfy recommends installing an 2 touches orange light (see wiring on page 14) and area lighting (see wiring on page 15).
CONNECTING AddITIONAl dEvICES General wiring diagram Ant . BU S 2 4 V dc Fla sh Bat t . La m p 2 3 0 Va c Ce ll 230v power supply Connecting the photoelectric cells Photoelectric cells must be connected to use the motor in automatic closing mode. 1 set of photoelectric cells TX: Transmitter cell RX: Receiver cell...
2 sets of photoelectric cells TX: Transmitter cell RX: Receiver cell 24 V 0 V C NO 24 V 0 V C NO 24 V 24 V AC/DC AC/DC AC/DC AC/DC recognition of the cells by the motor electronics The cells are recognised by revalidating the motor's operating mode (sequential or automatic, see page 12), or by performing a new self-learning procedure (see page 11).
Intercom This accessory is not compatible with solar power. The BUS input is a non-supplied dry contact control input. Backup battery The backup battery enables the gate to operate (one leaf at a time) if there is a power outage. It is integrated and connected directly to the motor's electronic unit.
SOlAr POwEr Never connect your motor to a 230 V feed when it is connected to a solar feed, as this may damage the motor's electronics. When the motor is running on the solar feed: - only the remote controls and radio control points can be used to control the gate (wired controls are deactivated), - the wired safety accessories (photoelectric cells, orange light) remain active, - the area lighting output and the 24V accessories output are deactivated.
dIAGNOSTIC ANd rEPAIrS Power the installation off during cleaning or other maintenance operations. dIAGNOSTICS rEPAIrS The motors are not responding to The remote control range is reduced - Check the remote control battery (see Replacing the battery, remote control commands user section, page 4).
Clear the settings The cleared settings are: the gate leaf travel and automatic closing of the gate. when to clear the settings. After the gate leaf travel has been programmed, if the opening stop setting or motor wiring has been modified. In case of spurious obstacle detection because of normal wear on the gate.
Page 21
Axovia 220B user manual CONTENTS GENErAl INfOrmATION _______________________________________________________________ 2 SAfETy INSTruCTIONS _______________________________________________________________ 2 rECyClING __________________________________________________________________________ 2 uSE ANd OPErATION _________________________________________________________________ 3 mAINTENANCE ________________________________________________________________________ 4...
Page 22
At Somfy, the pursuit of quality is a continuous process of improvement. Somfy's reputation has been built upon the reliability of its products and the Somfy brand is synonymous with innovation and technological expertise worldwide.
Page 23
uSE ANd OPErATION default operation in sequential mode By default, the gate will operate in sequential mode. Operation in "complete opening" mode with a 2- or 4-button remote control (fig. 1) Press the programmed button to open the gate fully. STOP STOP Operation in "pedestrian opening"...
Page 24
Specific operation Depending on the installed additional devices, the motorisation may operate in the following specific ways: Operation with safety cells Gate open: an obstacle placed between the cells will inhibit closing of the gate as the cells have detected a presence. Gate moving: If an obstacle is detected while the gate is opening, the gate will continue moving (cell status not recognised).
Need help?
Do you have a question about the HOME MOTION Axovia 220B and is the answer not in the manual?
Questions and answers