Figure 4-3
NOTICE
Bearing damage
Bearing currents can flow if the coupling between the motors of the tandem drive is not
insulated. This can damage the DE bearings of both motors.
• Use an insulated coupling to couple the motors.
4.13.5

Speed limits for converter operation

Observe the information on the rating plate regarding the speed limits for converter operation.
1FZ shaft height 280
Operating Instructions, 02/2022, A5E51698698A
Driven machine
Motor
Coupling
Schematic representation of a tandem drive
4.13 Converter operation
Insulated bearings
Insulated tachometer fitting
Insulated coupling
Preparing for use