Sensors
Clamping bushes
Wiring harnesses
Electronic control module technical data
Voltage:.................................................24 ± 6 volts
Thermal operating range:.................. -40 to 167 °F
Protection system for sealed multi-pin plug ac-
cording to DIN 40050
Electrical connection is made through a 35 pin
plug
Maintenance: .................................................. none
Solenoid control valve technical data
Voltage:....................................24 (+4.8, -2.4) volts
Current:.............................................................. DC
Rated current:........................................ 1.65 amps
Protection system according to DIN 40050
Maximum service pressure:........10 bars (145 psi)
Thermal operating range:.................. -40 to 176 °F
Electrical connector: ........................894 601 010 2
Maintenance: .................................................. none
Sensor technical data
Two cored screened cable:..........AWG 18 (1 mm
Force needed to tear out lead:....... 11.2 lbs (50 N)
Force needed to pull off shrink-fitted tube: .............
........................................................ 11.2 lbs (50 N)
Thermal operating range:.................. -40 to 176 °F
Protection system according to DIN 40050
Preheating Systems (Optional)
Espar (Eberspächer)
Heater: ............................................... Model D12W
Heating capacity: ..........................................12 kW
Heating output:..................................41,000 Btu/hr
Fuel type:...................................... Same as engine
Fuel consumption:.............................0.44 U.S. gal.
Rated voltage: ...................................... 24 ± 4 volts
Electric power consumption:..................... 55 watts
(-40 to 75 °C)
Webasto
Heater:........................................Model DBW 2020
Heating capacity: ...................................... 23.3 kW
Heating output:..................................80,000 Btu/hr
Fuel type:...................................... Same as engine
Fuel consumption:...............................0.8 U.S. gal.
Rated voltage: ...................................... 24 ± 4 volts
Electric power consumption:................... 120 watts
(-40 to 80 °C)
2
)
(-40 to 80 °C)
5 - 6
(1,65 liters) / hour
(3 liters) / hour