Safety Devices - TEXA KONFORT 700R Technical Manual

Recharging and maintenance stations
Hide thumbs Also See for KONFORT 700R:
Table of Contents

Advertisement

• During use, do not move out of the TS operating temperature range and do not
exceed the PS maximum operating pressure (see plate on the device).
• Only use refrigerants R134a or R1234yf.
• Make sure you use the correct refrigerant for the model of the device you are
using.
• Make sure you use the correct refrigerant for the vehicle you are working on.
• Connect the hoses correctly by following the colours indicated: Blue hose - LP
connection, red hose - HP connection.
• Connect both hoses to the corresponding connections of the same group (both
hoses connected to GAS1 group or both hoses to the GAS2 group).
• Make sure all the valves are closed before connecting the device to the A/C
system or to an external cylinder.
• Make sure the operating phase has come to an end and the valves are closed
before disconnecting the device; this should be done to avoid the refrigerant from
spreading into the atmosphere.
• It is absolutely forbidden to modify the calibration of the safety valves and the
control systems.
• Do not smoke near the device or during the operating phases.
• Do not use the device near open flames, sparks, hot surfaces: the refrigerant
decomposes at high temperatures, letting off toxic chemical substances that are
harmful to people and the environment.
• Do not expose the device to direct sunlight, rain and bad weather conditions.
• Disconnect the hoses with extreme caution; they may contain refrigerant under
high pressure.
• Make sure the couplers are not open when the hoses are placed back around the
service hose holder.
• Do not leave the device connected to the power supply if you do not intend to use
it immediately.
• To move the device use the specific handle only and balance the station on its
wheels.
• If storing the device for a long period of time, disconnect it from the power mains
and put it in a safe place, where it is not exposed to outside weather conditions.

2.4.1 Safety Devices

The KONFORT 700R series recharging stations are equipped with the
following safety features:
• Safety pressure switch: stops the compressor when the pressure reaches a
cut-off level.
• Safety valve: opens completely in the event the PS value is reached.
• Main switch: allows you to cut off the power supply from the power mains in case
of an emergency or in order to carry out maintenance.
Tampering with the above mentioned safety devices of any kind is strictly
forbidden.
en