SE58 L INDEX INTRODUCTION SAFETY INFORMATION SAFETY CONVENTION TECHNICAL CHARACTERISTICS TORQUES SE58 L CONSTRUCTION MV110 CONSTRUCTION (STAINLESS STEEL VERSION) INTERNAL LAYOUT ELECTRICAL CONNECTION AND GROUNDING INSTRUCTIONS INTERNAL LITHIUM BATTERY ELECTRICAL CONNECTION TRANSMITTER- SENSOR DIGITAL INPUT ON/OFF OPERATION OUTPUTS WIRING...
Page 3
MENU 5 - ALARMS MENU 6 - INPUTS MENU 7 - OUTPUTS BATCHING MENU 8 - COMMUNICATION SE58 L MODBUS PROTOCOL MENU 9 - DISPLAY MENU 10 - DATA LOGGER USING DATA LOGGER BY MCP INTERFACE MCP INTERFACE MENU 11 - FUNCTION...
SE58 L INTRODUCTION • These operating instructions and description of device functions are provided as part of the scope of supply. • They could be modified without prior notice. The improper use, possible tampering of the device or parts of it and substitutions of any components not original, renders the warranty automatically void.
Page 5
SE58 L • The specialists must have read and understood these Operating Instructions and must follow the instructions it contains. The Operating Instructions provide detailed information about the transmitter. If you are unclear on anything in these Operating Instructions, you must call the Bürkert service department.
SE58 L TECHNICAL CHARACTERISTICS Electrical Characteristic Converter classification: class I, IP67 (where: 6 = totally protected against dust, 7 = Protected against the effects of temporary immersion) / IP68 (where: 6 = totally protected against dust, 8 = continuous immersion 1.5 m; 1 h) for aluminum and PA6 housing, installation category (overvoltage) II, rated pollution degree 2.
SE58 L Data Plate The device label contain the following information: Type SE58 L (B0A1C2B1A4A0) Transmitter model ANZ000001 Transmitter serial number XXXXXX Identification code Power 44-66 Hz 100-240VAC 5VA Min-Max supply voltage range-supply voltage type-max. power consumption MaxTa 50°C...
Page 13
SE58 L TORQUES To guarantee the housing’s IP degree the following torques are required: Housing Screws Screws Cable HOUSING Version screws Terminal block for display Glands USB-B MATERIAL Screws Cap (3) cover (2) frame ALUMINIUM 6 Nm 5.5 Nm 3 Nm 0.8 Nm...
SE58 L INTERNAL LAYOUT Internal Transmitter Views Remove the main housing cover by removing the 4 screws as shown here below. POWER SUPPLY BOARD MINI USB-B TERMINAL BLOCKS MAIN POWER SUPPLY POWER SUPPLY CABLE English...
Page 18
SE58 L ELECTRICAL CONNECTION AND GROUNDING INSTRUCTIONS Always ensure that the transmitter and the sensor are grounded (earthed) correctly. The grounding of the sensor and transmitter must ensure that the device and liquid are equipotential. ORING 4700 L(+) N(-)
SE58 L ATTENTION! • The internal lithium battery is rechargeable and should never be disconnected from the transmitter card when it is powered by the mains voltage. If this operation should be carried out it could irreparably damage the transmitter board.
Page 21
SE58 L ELECTRICAL CONNECTION TRANSMITTER- SENSOR Sudden movements of the electrodes cable could introduce noise. SH = SHIELD OF CABLE internally connected to ground. ELECTRODES RS485 22 21 20 4-20 OUTPUTS OUTPUT OUT2 (+) 4-20 +24V OUT1 (+) 4-20*...
SE58 L DIGITAL INPUT ON/OFF OPERATION INTERNAL POWER SUPPLY EXTERNAL POWER SUPPLY 10KΩ 15(+) 10KΩ 10KΩ 3-40Vdc (ON) 0/1.5Vdc (OFF) 16(+) RESET TOTALIZERS Necessary conditions for enabling the function Block • POS. 6.1 see page 35 (T+; total positive set on)
SE58 L Measure freq. T MIN MUST BE 50HZ 20ms T > Tmin 10HZ 100ms 200ms 500ms OUTPUTS WIRING Digital outputs • Opto-insulated output with floating collector and emitter terminals freely connectable 18 OUT 1(+) • Maximum switching voltage: 30 V 19 OUT 2(+) •...
SE58 L RS485 MODBUS MODULE (OPTIONAL) Positioning to ‘ON’ the termination switches 1 and 2, a 120Ω resistance is activated in the RS485 circuit (see terminal block). TERMINATION SWITCH TERMINAL BLOCK RS485 English...
Page 25
SE58 L CONNECTORS MIL The following are the links of the MIL connectors IP68 SENSOR SIGNALS Connector Contact A from terminal 1 of the transmitter (electrode 1) 6 poles Contact F from terminal 2 of the transmitter (electrode 2) Contact A from terminal 3 of the transmitter (COM.
Page 26
SE58 L START VISUALIZATION PAGES The direct exposure of the transmitter to the solar rays, could damage the liquid crystal display. The visualization pages can be changed according to device’s setup. Push to change visualization Flow rate direction +/-...
Page 27
SE58 L Push to change visualization Totalizer Total + Totalizer Partial + Totalizer Total - Totalizer Partial - Electrodes Voltage Electrodes Resistance n°Alarm Alarm List Date and Time Direct Total Totalizer Direct Partial Totalizer Reverse Total Totalizer Reverse Partial Totalizer The visualization page about batching is described in the dedicated section “BATCHING”...
Page 28
SE58 L MEANING OF FLAGS FLAG DESCRIPTION FLAG DESCRIPTION EMPTY PIPE MIN FLOW ALARM FILE UPLOAD MAX FLOW ALARM FILE DOWNLOAD VIRTUAL DISPLAY CONNECTED BATTERY RECHARGE (FLASHING) FLOW RATE OVERFLOW LOW BATTERY (FIXED) FLOW RATE SIMULATION (FLASHING) PULSE 1 OVERFLOW...
SE58 L ACCESS TO THE CONFIGURATION MENU The configuration can be done in two different ways: • By keypad of transmitter • By MCP interface (Virtual display of device) Access Via Keypad SHORT PRESSING (< 1 SECOND): SHORT PRESSING (< 1 SECOND): SHORT PRESSING (<...
Page 30
SE58 L ACCESS VIA MCP INTERFACE (VIRTUAL DISPLAY) MCP is a Windows® software that allows to set all the transmitter functions and personalize the menu. The MCP program is required for the blind version of the transmitter. To use MCP interface consult the relevant user manual.
2.5% of flow rate. The SE58 L can show a 5 digits display for flow rate units; this mean the maximum flow rate value that can be represented on the display is 99999 (no matter the positioning of the decimal point). The minimum is 0.0025.
Page 32
SE58 L TRANSMITTER ACCESS CODE The access for programming the device is regulated by six access levels logically grouped. Every level is protected by a different code. • Access Level 1-2-3-4 Freely programmable by user Access Code Set : Menu 13 System The CODE is Settable by keyboard or MCP interface.
Page 33
SE58 L The following example shows how to change the full scale by Quick Start menu; the second illustrates how to change the function by the Main menu. EXAMPLE: modifying the full scale value from 4dm³/s to 5dm³/s, from the “Quick start menu”...
Page 34
SE58 L EXAMPLE: modifying the full scale value from 4dm³/s to 5dm³/s, from the “Main Menu” (quick start menu enabled) Press arrow keys to select the Press the ENTER button to cell in which to insert the number access the Quick Start menu of the access code.
SE58 L FUNCTIONS MENU The main menu is selected from the Quick start menu by pressing the key and entering the access code, if it’s required. Note: Some functions are displayed only with other functions active, or with optional modules.
Page 36
SE58 L S C A L E S Full scale flow rate for range 1 F S 1 g / s 4 9 0 8 . 7 Batching quantity B . q t y d m 3 1 . 0 0 0 0 0...
Page 37
SE58 L O U T P U T S Output 1 function selection O u t 1 P U L S E S + Output 2 function selection O u t 2 P U L S E S - OUTP.
Page 38
SE58 L D A T A L O G G E R 10.1 Data logger sampling enable D . l o g g e r e n . 10.2 Measure units recording enable M e a s . u n i t s 10.3...
Page 39
SE58 L S Y S T E M 13.1 Daylight saving time change D a y l . S a v i n g = 13.2 Localized time zone T i m e z o n e = h + 01.00 13.3...
SE58 L FUNCTIONS DESCRIPTION Here below the explanation on how the rows of menu are described. Menu visualized on the transmitter (from 1 to 13) MENU 1 - SENSOR (POS. 1.1) [S. model xxx] [SMODL] Sensor MODeL Access level...
SE58 L MENU 1 - SENSOR (POS. 1.1) Sensor MODeL [S. model xxx] [SMODL] Enter the first two characters of the serial number of the sensor as on the sensor label. (POS. 1.2) LIning MAterial Type [Lining= UNSPEC.] [LIMAT] Flow sensor lining material type.
Page 42
SE58 L (POS. 1.14) CoeFFicient KC [KC= +/- xx.xxx] [CFFKC] Calibration Factor. This function is activated if the sensor model is NOT present on the sensors table standard parameters (POS. 1.15) Coils EXCitation Current [C.Curr.= mA xxx.x] [CEXCC] Coils’ excitation current. This function is activated if the sensor model is NOT present on the sensors table standard parameters (POS.
Page 43
SE58 L (POS. 1.26) SET KJ value [Zero point cal.] [SETKJ] This feature appears only when the process conditions are as follow: measure filters recommended (Damping) set to SMART 2 second / 5 second stable flow rate and lower than 0.1% of the absolute scale (10 m/s)
SE58 L MENU 2 - UNITS WARNING: The totalizer value is updated and changed depending on the setting of unit value. The scale change may cause accuracy loss depending of rounding up. For example, if T +=0,234 liters with 3 decimals, it become T += 0.001 m³ losing 0.234 liters in rounding up.
Page 45
SE58 L (POS. 2.11) Totalizer Total Positive Decimal Point position [P+ D.P.= x] [TPPDP] Setting partial positive totalizer decimal point position. Example: P+D.P.= 3 visualized value P+dm³ 0.000 / P+D.P.= 2 visualized value P+dm³ 0.00 (POS. 2.12) Totalizer Total Negative Unit of measure Type...
Page 46
SE58 L MENU 3 - SCALE (POS. 3.1-3) Flow Rate Full Scale 1-2 [FS1-2= l/s xxxx.x] [FRFS1-FRFS2] The FS2 (full scale flow rate 2) is active with POS. 6.6 see page 35, enabled. The full scale is used to indicate the maximum meter’s flow rate. The full scale should be chosen carefully as its parameters are used for several other parameters.There are three fields to fill in order to set this parameter, from...
Page 47
SE58 L (POS. 3.2) BaTching QuanTitY [B.qty=xxxxx] [BTQTY] This function is enabled when output1 is set to “BATCHING”. It allows to set the unit of measure and the batching quantity. (POS. 3.4-3.6) OutPut 1-2 Pulse Value [Pls1-2= dm³ x.xxxxx] [OP1PV-OP2PV] The functions on POS.
SE58 L MENU 4 - MEASURE (POS. 4.1) Measure Filter DaMPing [Damping=OFF/SMART/(TIME)] [MFDMP] This section of manual is extremely important because the correct setting of the filters allows to obtain a proper response of the device to the measured flow rate and the specific requirements of use; as a general rule, consider that, starting from Damping = OFF (no filter applied to the measure), successive values, introduce increasing damping.
Page 49
SE58 L (POS. 4.2) Measure Filter CUt-off Threshold [Cut-off=% xxx] [MFCUT] Setting the low flow cut-off threshold. This function is useful to avoid that when the flow is close to zero, tiny movements of liquid (due for example to vibrations of the pipe) can cause an increasing of the totalizers. The allowed range for this function is 0-25% of full scale set.
SE58 L MENU 5 - ALARMS (POS. 5.1) Flow Rate Alarm maX Positive [Max+=technical unit XXX] [FRAXP] Maximum value alarm set for positive flow rate set (expressed in technical units). When the flow rate value exceeds such a threshold, then an alarm message is generated. Setting this parameter to zero disables the alarm generation.
SE58 L MENU 6 - INPUTS WARNING! This menu is not enabled when the batching function is active. [T/P+/RESET=ON/OFF] [VTTPE] [VTPPE] POS. 6.1-2) Volume Totalizer Total /Partial Positive reset Enable When one of this function is enabled, the related positive totalizer may be reset through the on/off input.
SE58 L MENU 7 - OUTPUTS (POS. 7.1) OUTput 1 Function [Out1=XXXXXX] [OUT1F] Function choice corresponding to digital Output 1. The functions are listed in the table below (POS. 7.2) OUTput 2 Function [Out2=XXXXXX] [OUT2F] Function choice corresponding to digital Output 2. The functions are listed in the table below.
Page 53
SE58 L BATCHING Through this function, is possible to set the volume quantity that must be delivered, managing the opening and the closing of the valve. To activate it, follow these instructions: Enter to the main menu; Select Output menu;...
SE58 L BATCHING QUANTITY SETTINGS: Enter to the 3. Scale menu; By display Set the B.qty (batching quantity) value “BTQTY?” VALUES: Through this command it can be set both By MCP command 0:’ml’|1:’cm3’|2:’l’|3:’dm3’|4:’dal’|5:’hl’|6:’m3’|7:’ the unit measure or the quantity (see MCP Ml’...
Page 55
SE58 L The batching process automatically stops the valve when the batching quantity reaches the set value. If the delivered volume doesn’t match to the required one, it’s necessary to notice empirically the value to set. In this way It is possible to compensate any “delays” in the process after the stop signal.
Page 56
SE58 L BATCHING ALARMS NAME DESCRIPTION NOTES Active alarms automatically close the It activates after 4 seconds from the start Batching time-out valve (actuator) command, when any flow is detected Both alarms can be visualized remotely, setting the usc2 function on “HARD W.
Page 57
SE58 L CURRENT VALUES IN mA ASSOCIATE TO THE % FULL SCALE VALUE POSSIBLE FIELD REVERSE FLOW VALUE ZERO DIRECT FLOW VALUE ≤-210% -100% +100% ≥+210% Out.mA = 0 ÷ 20 + Out.mA = 0 ÷ 22 + Out.mA = 4 ÷ 20 + *Out.mA = 4 ÷...
Page 58
SE58 L MENU 8 - COMMUNICATION (POS. 8.1) HART Preamble [HART pr.=XXXXXX] [HARTP] Number of preamble (Hart function) (POS. 8.2) HaRT Output Control [HART O.C=ON/OFF] [HRTOC] Hart bus output control 4-20mA. (POS. 8.3) DeVice ADDress [Dev. Addr=XXXXXX] [DVADD] Device communication address number.
SE58 L MENU 9 - DISPLAY (POS. 9.1) Layout LANGuage [Language= ITA/EN] [LLANG] Choice of the language. There are 8 languages available: GB = English, IT = Italian, TR = Turkish, PL = Polish, DE = German, FR = French, PT = Portuguese, ES = Spanish.
Page 60
SE58 L MENU 10 - DATA LOGGER (POS. 10.1) Data LOGger Enable [D.logger en= /OFF] [DLOGE] This function enables data logger The following functions are activated by [D.loger en= ON] [Meas. units= ON] [DLUME] (POS. 10.2) Data Logger Units of Measure Enable Measure unit recording enable (POS.
Page 61
SE58 L (POS. 10.15) Data logger Sensor Test Results Enable [Log STR= ON] [DSTRE] Enable logging of sensor test results (POS. 10.16) Data logger Board TemperatureS Enable [Log BTS= ON] [DBTSE] Enable logging of board temperature (POS. 10.17) Data logger Internal Board Voltages...
Page 62
SE58 L USING DATA LOGGER BY MCP INTERFACE Data are stored on micro SD card; the organization is based on “tree-structure”: the system create a daily folder where it save events and data logger . The data can be downloaded by MCP interface.
Page 63
SE58 L C=Today Last; this option allows to download the latest files, recordered after the last download All; this option allows the download of all the current day of the file D=Save path: This option allows you to save files to the folder on your PC...
Page 64
SE58 L View downloaded files setting download data logger. Note: The fields are in a fixed position, regardless if the above fields are active or not. The disabled fields are empty (delimited by the separator but without data). N°Record. View progressively the number of registered records.
Page 65
SE58 L Voltage measured on electrode E1. Form fields when is active the recording of data on the input voltage (diagnostic value). Voltage measured on electrode E2. Form fields when is active the recording of data on the input voltage (diagnostic value).
Page 66
SE58 L Negative supply voltage of the analog circuits. Form fields when the data on the board’s internal power supply voltage measurements flag is ON (diagnostic values). Voltage measured on the battery B1 (NOT rechargeable battery). Fields when the data on the board’s internal power supply voltage measurements flag is ON (diagnostic values).
Page 67
SE58 L MENU 11 - FUNCTION The following functions are activated by first pressing the “ENTER” and then the “ESC” when the screen appears “confirm” to start the function. (POS. 11.1) Volume Totalizer Total Positive Reset [VTTPR] [T+ RESET= ON] This function allows to reset the total positive totalizer for direct flow rate (+) (POS.
SE58 L MENU 11 - Function: ONLY MCP FUNCTIONS Sensor ReFerence Data Save [MCP ONLY] [SRFDS] Saving the sensor reference data. “meter data” page 80 MENU 12 - DIAGNOSTIC (POS. 12.1) AutoTeSt Immediate Command [Self Test] [ATSIC] Meter auto-test function. This function stops the normal functions of the meter and performs a complete test cycle on the measure input circuits and on the excitation generator.
Page 69
SE58 L (POS. 12.6) Diagnostic Communication VaLueS [ Disp. comm. vars ] [DCVLS] Create a list of diagnostic values on the device communication. PPP link status MCPI socket status Following are the states for the PPP link and MCPI to connect the device.
Page 70
SE58 L (POS. 12.9) SD memory STAtus [SD card info] [SDSTA] This function shows the status of the SD card as shown in the following figure. Total Size Available memory Cluster Memory Use time remaining SD card * Hours Minutes Seconds The statistical calculation is performed every time the command SDSTA is invoked.
Page 71
SE58 L (POS. 12.11) SeRial NUMber [ S/N= xxxxxx ] [SRNUM?] View Board serial number. (read only) (POS. 12.12) Total WorKing TiMe [ WT= xxxx: xx: xx: xx ] [TWKTM?] View Total working time device. (read only) MENU 13 - SYSTEM (POS.
Page 72
SE58 L PC SERVER IP ADDRESS DEVICE IP CLIENT ADDRESS (POS. 13.14) CoeFFicient KT [KT=X.XXXXX] [CFFKT] Gain correction coefficient (calculated automatically) (POS. 13.15) CoeFFicient KS [KS=X.XXXXX] [CFFKS] Correction coefficient constant deviceal (POS. 13.16) CoeFFicient KR [KR=X.XXXXX] [CFFKR] Correction coefficient constant deviceal DIGITAL ANALOG Transmitter (Correction Parameters)(13.17-18-19-20)
Page 73
SE58 L MENU 13 - SYSTEM: ONLY MCP FUNCTIONS Unique Identity KEY [MCP ONLY] [UIKEY] Device Unique Identity key HardWare SET [MCP ONLY] [HWSET] Device hardware configuration HardWare CODe [MCP ONLY] [HWCOD] Device hardware code CALibration eXecution status Memory...
Page 74
SE58 L Access CODE [MCP ONLY] [ACODE] Input the right access code Example set quick start menu function for mcp. ACODE=0; FCODS=[MCP COMMAND]; QSFNS=1 Access Code INSERT MCP Command of Quick Start FuNction Selection the function to be activated in the QS menu.
Page 75
SE58 L Volume Totalizer Total Negative Set [MCP ONLY] [VTTNS] This function allows to set the value of total negative totalizer Volume Totalizer Partial Negative Set [MCP ONLY] [VTPNS] This function allows to set the value of partial negative totalizer...
Page 76
SE58 L Calibration GAin Register 0 [MCP ONLY] [COFR1] Calibration offset register 1 Calibration GAin Register 0 [MCP ONLY] [CGAR0] Calibration gain register 0 Calibration GAin Register1 [CGAR1] [MCP ONLY] Calibration gain register 1 Calibration GAin Register 2 [MCP ONLY]...
Page 77
SE58 L MENU 14 - FILE (ONLY MCP) File Transfer ABoRt [MCP ONLY] [FTABR] This function allows to abort the current file transfer File Transfer STAte [MCP ONLY] [FTSTA] This function allows to show the file transfer state Read Last EVenTs...
Page 78
SE58 L ConFiGuration file WRite [MCP ONLY] [CFGWR] This function allows to save a file with the configuration data ConFiGuration file ReaD [CFGRD] [MCP ONLY] This function allows to read the configuration from a file FuNCtion list file WRite...
Page 79
SE58 L Volume Totalizer Total Positive Value [MCP ONLY] [VTTPV] Totalizer T+ read value Volume Totalizer Partial Positive Value [MCP ONLY] [VTPPV] Totalizer P+ read value Volume Totalizer Total Negative Value [MCP ONLY] [VTTNV] Totalizer T- read value Volume Totalizer Partial Negative Value...
Page 80
SE58 L Main power status [MCP ONLY] [MPWRS] Status of main power supply INput RESistance [MCP ONLY] [INRES] Equivalent Input resistance of liquid measured by electrodes INput VoLtageS [MCP ONLY] [INVLS] Electrodes input voltages System Battery Voltage [MCP ONLY]...
SE58 L METER DATA The "METER DATA" system allows the import of data up to level 4, included, (working and factory parameters of the card) of the converter to another device and the restoration of the data of a meter in case the electronic card needs to be replaced .
Page 82
Remove the 4 screws (“SE58 L construction” pag. 14) to remove the main housing. Attention of any electrical cables. Remove the 4 screws (see “SE58 L construction” pag. 14) to remove the SE58 L board. Attention of any electrical cables. Remove the SD card and insert the new SE58 L board.
Page 83
B.I.V. (BUILT-IN VERIFICATOR) BIV, abbreviation for Built In Verificator, is available as option for SE58 L transmitters and must be enabled by the manufacturer. It is also necessary that the SD card is activated to store saved data. The analysis of collected data performed by a dedicated software running on another device (PC).
Page 84
SE58 L Opening and reading manually the files STESTLOG.CSV The list below describes the steps for reading STESTLOG.CSV file. • OPEN INTERFACE STARTING THE PROGRAM MCP • FOLLOW THE STEPS HERE BELOW Select Sensor Verify Today Date Range Download of the les...
Page 85
SE58 L Reference voltage electrode E2 The unit of voltage E2 (V) (#) Differential voltage E1-E2 The unit of voltage (V) (#) Common mode voltage (E1 + E2) / 2 The unit of resistance (ohm) (#) Resistance measured between E1 and the common...
Page 86
SE58 L Standard and internal check to the device limits The measured data are compared with the reference values previously stored. The deviation of different variable measured,shall be within the following range: Coil temperature (using resistance reading): within limits compatible with the lining material Current up times: change% detected resistance coils + 10% (tolerance range) Resistance between electrodes and common: between 0.3 and 3.0 times the reference early strength...
Page 87
SE58 L ALARM MESSAGES (CAUSES AND ACTIONS TO BE TAKEN) MESSAGE CAUSES ACTION TO TAKE NO ALARMS All works regularly [000] SYSTEM RESTART [001] INTERNAL PS FAIL Internal supply voltage error Contact the service Set the system clock from the transmitter...
Page 88
SE58 L Battery voltage (rechargeable)> [022] BATTERY V>MAX Contact the service to Replace the battery max. Allowed Battery charge current> max. [023] BATTERY I>MAX Contact the service to Replace the battery allowed Main supply voltage (+ 5V) out of [024] MAIN PS V.ERR...
Page 89
SE58 L ERROR CODE TEST SYSTEM OF SENSOR The codes are in hexadecimal format, the meaning is given for each bit. There are several possible error simultaneous combinations (more bits active) then that will give the combined numerical codes.
Page 90
SE58 L At the end of its lifetime, this product shall be disposed of in full compliance with the environmental regulations of the state in which it is located. English...
SE58 L MANUAL VERSION VERSION DATE DESCRIPTION SE58L_EN_BU_R00_1.02.XXXX 07/04/2021 First Edition Update for electrical safety certification. SE58L_EN_BU_R01_1.04.XXXX 18/08/2021 Firmware update for adding Mbus protocol SE58L_EN_BU_R02_1.04.XXXX 08/10/2021 Changes to data relating to digital output English...