Troubleshooting; Maintenance Instructions - Galvin Engineering Flowmatic TZ-FLOWSENC24 Installation Manuallines

Ss face plate w/ concealed 24v ac wall sensor
Table of Contents

Advertisement

Product Installation Guidelines
TROUBLE SHOOTING
PROBLEM
Sensor Not
Responding
False
Activation
No water flow

MAINTENANCE INSTRUCTIONS

Sensor:
The Electronic Sensor is a non serviceable product. If damaged the sensor must be replaced.
Turn power off at GPO.
Unscrew the two fixing screws. The silicon seal may have to be cut with care to free the sensor.
Unplug the solenoid plug and transformer plug from the rear of the sensor. Generally, if the sensor has been
damaged by an electrical surge, it is recommended that the transformer be replaced at the same time.
Replace the sensor and reconnect the new sensor. Plug the solenoid and transformer plugs back onto the
rear of the sensor. Fix the sensor panel back onto the galvanised inwall box with the existing screws.
Important: Seal the stainless steel face panel and screws using silicon, ensuring it has a water tight
seal.
Note: Before attempting to replace any of these items check that you have access to re-run the
connection leads. If you do not have access or you have any doubts please contact Galvin Specialised
for advice before commencing replacement.
© Galvin Engineering Pty Ltd
CAUSE
Damaged or scratched lens
Sensor lead damaged
No Power
Waving Hand too fast past the sensor
Transformer faulty
Electrical interference
Reflection from a light source
Sensor not responding
No power
Power supply leads joined incorrectly
Water or structural damage to
electrical components
Incorrect connections
Damage to sensor lead or power
supply lead
Water corroded electrical
connections
RECTIFICATION
Replace Sensor Unit
Replace sensor lead
Check power is reaching transformer
Slow down the action in front of the sensor
Replace transformer
Ensure electrical suppressors are installed
correctly
Re-align sensor or shield light source
Check fault relating to sensor
Check power is reaching transformer
Replace electronic components
Replace damaged electrical components
Check all connections
Check and replace lead & controllers
Replace electronic components
Version 1.1, 30 April 2021, Page 10 of 11