3.3.14
CAN Connectors
CAN Bus Connectors
CN29, CN30
Pin
Signal
1
GND
2
CAN_H
3
CAN_L
4
+5V_SW
Mating connector: MOLEX 43025-0400 or equivalent with 43030 female crimp terminal
Mating connector: MOLEX 51021-0300 receptacle with MOLEX 50079-8000 female crimp terminals.
A 120 termination resistor can be placed between CAN_H and CAN_L signals. It can be connected or disconnected from the line by using JP2 jumper (Jumper
inserted = termination connected).
Signals Description:
CAN_H: High-Level CAN bus line
CAN_L: Low-Level CAN bus line
SBC-D23
SBC-D23 User Manual - Rev. First Edition: 1.0 - Last Edition: 1.0 - Author: S.B. - Reviewed by P.Z. - Copyright © 2021 SECO S.p.A.
SBC-D23 board can offer a single CAN Bus duplicated on two connectors, in order to connect directly
to two devices simultaneously using the same Bus.
The CAN Bus controller is programmed inside the on-board microcontroller, while the physical interface
comes through a High-Speed CAN transceiver, type NXP TJA1051, which offers also improved EMC and ESD
performances.
The two CAN Bus Connectors are 4-pin Micro-fit 2x2 connector type Molex 43045-0424 or equivalent, as shown in
the figure.